Effect of skin temperature on multifrequency bioelectrical impedance analysis
The DOI matches its Crossref record.
Abstract
This study assessed the effects of changes in skin temperature on multifrequency bioimpedance analysis (MF-BIA) and on the prediction of body water compartments. Skin temperature (baseline 29.3 +/- 2.1 degrees C) of six healthy adults was raised over 50 min to 35.8 +/- 0.6 degrees C, followed by cooling for 20 min to 26.9 +/- 1.3 degrees C, by using an external heating and cooling blanket. MF-BIA was measured at both distal (conventional) and proximal electrode placements. Both distal and proximal impedance varied inversely with a change in skin temperature across all frequencies (5–500 kHz). The change in proximal impedance per degree centigrade change in skin surface temperature was approximately 60% of distal impedance. The change in measured impedance at 50 kHz erroneously increased predicted total body water (TBW) by 2.6 +/- 0.9 liters (P < 0.001) and underpredicted fat mass by 3.3 +/- 1.3 kg (P < 0.0001). Computer modeling of the MF-BIA data indicated changes in predicted water compartments with temperature modifications; however, the ratio of extracellular water (ECW) to TBW did not significantly change (P < 0.4). This change in impedance was not due to a change in the movement of water of the ECW compartment and thus probably represents a change in cutaneous impedance of the skin. Controlled ambient and skin temperatures should be included in the standardization of BIA measurements. The error in predicted TBW is < 1% within an ambient temperature range of 22.3 to 27.7 degrees C (72.1–81.9 degrees F).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Is bioelectrical impedance accurate for use in large epidemiological studies?
Dehghan, M., & Merchant, A. T. (2008) · Nutrition Journal · doi:10.1186/1475-2891-7-26 · Cited by 505
Relationship between Overnight Rostral Fluid Shift and Obstructive Sleep Apnea in Nonobese Men
Redolfi, S., Yumino, D., Ruttanaumpawan, P., Yau, B., Su, M.-C., Lam, J., & Bradley, T. D. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200807-1076oc · Cited by 406
Pichard, C., Kyle, U. G., Morabia, A., Perrier, A., Vermeulen, B., & Unger, P. (2004) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/79.4.613 · Cited by 392
Clinical characteristics influencing bioelectrical impedance analysis measurements
Kushner, R., Gudivaka, R., & Schoeller, D. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.423s · Cited by 338
Self-citationSawka, M. N., Cheuvront, S. N., & Carter, R. (2005) · Nutrition Reviews · doi:10.1111/j.1753-4887.2005.tb00152.x · Cited by 336
Sergi, G., De Rui, M., Stubbs, B., Veronese, N., & Manzato, E. (2017) · Aging Clinical and Experimental Research · doi:10.1007/s40520-016-0622-6 · Cited by 291
Hydration Assessment Techniques
Armstrong, L. E. (2005) · Nutrition Reviews · doi:10.1111/j.1753-4887.2005.tb00153.x · Cited by 292
Contemporary methods of body composition measurement
Fosbøl, M. Ø., & Zerahn, B. (2015) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12152 · Cited by 279
(2006) · Routledge eBooks · doi:10.4324/9780203970157 · Cited by 258
Earthman, C. P. (2015) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607115595227 · Cited by 234
“The reader is referred to several excellent sources that describe errors associated with protocol violations.(106,108,109,113) In general, the application of all varieties of bioimpedance techniques for the estimation of whole-body compartments has been accepted as reasonably accurate for the assessment of healthy non…”
BackgroundDehydration and rehydration in competative sport
Maughan, R. J., & Shirreffs, S. M. (2010) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2010.01207.x · Cited by 167
“However, acute changes in body water content are not reliably detected by the method, and it is sensitive to posture (Shirreffs & Maughan, 1994), skin temperature (Gudivaka et al., 1996) and other factors unrelated to body water content (O’Brien et al., 2002).”
MethodAssessment of hydration status in a large population
Baron, S., Courbebaisse, M., Lepicard, E. M., & Friedlander, G. (2015) · British Journal of Nutrition · doi:10.1017/s0007114514003213 · Cited by 166
Vaquero-Cristóbal, R., Albaladejo-Saura, M., Luna-Badachi, A. E., & Esparza-Ros, F. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17217777 · Cited by 32
Metadata
- Authors
- Gudivaka, R., Schoeller, D., & Kushner, R. F.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1996-08-01
- Volume
- 81
- Issue
- 2
- Pages
- 838-845
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1859448357
- Cited by
- 114
- References
- 0
- FWCI
- 1.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.