Effect of microgravity and hypergravity on deposition of 0.5- to 3-μm-diameter aerosol in the human lung
The DOI matches its Crossref record.
Abstract
Darquenne, Chantal, Manuel Paiva, John B. West, and G. Kim Prisk. Effect of microgravity and hypergravity on deposition of 0.5- to 3-μm-diameter aerosol in the human lung. J. Appl. Physiol. 83(6): 2029–2036, 1997.—We measured intrapulmonary deposition of 0.5-, 1-, 2-, and 3-μm-diameter particles in four subjects on the ground (1 G) and during parabolic flights both in microgravity (μG) and at ∼1.6 G. Subjects breathed aerosols at a constant flow rate (0.4 l/s) and tidal volume (0.75 liter). At 1 G and ∼1.6 G, deposition increased with increasing particle size. In μG, differences in deposition as a function of particle size were almost abolished. Deposition was a nearly linear function of the G level for 2- and 3-μm-diameter particles, whereas for 0.5- and 1.0-μm-diameter particles, deposition increased less between μG and 1 G than between 1 G and ∼1.6 G. Comparison with numerical predictions showed good agreement for 1-, 2-, and 3-μm-diameter particles at 1 and ∼1.6 G, whereas the model consistently underestimated deposition in μG. The higher deposition observed in μG compared with model predictions might be explained by a larger deposition by diffusion because of a higher alveolar concentration of aerosol in μG and to the nonreversibility of the flow, causing additional mixing of the aerosols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The health effects of combustion-generated aerosols
Kennedy, I. M. (2007) · Proceedings of the Combustion Institute · doi:10.1016/j.proci.2006.08.116 · Cited by 377
Physiological, Pharmacokinetic, and Pharmacodynamic Changes in Space
Graebe, A., Schuck, E. L., Lensing, P., Putcha, L., & Derendorf, H. (2004) · The Journal of Clinical Pharmacology · doi:10.1177/0091270004267193 · Cited by 113
“0 μm).(153) The impact of these changes on the effectiveness of drugs targeted to the lungs, such as inhaled corticosteroids, has not been studied yet.”
BackgroundLinnarsson, D., Carpenter, J., Fubini, B., Gerde, P., Karlsson, L. L., Loftus, D. J., Prisk, G. K., Staufer, U., Tranfield, E. M., & van Westrenen, W. (2012) · Planetary and Space Science · doi:10.1016/j.pss.2012.05.023 · Cited by 95
Self-citationDeposition of inhaled particles in the human lung is more peripheral in lunar than in normal gravity
Darquenne, C., & Prisk, G. K. (2008) · European Journal of Applied Physiology · doi:10.1007/s00421-008-0766-y · Cited by 53
Self-citationGoswami, N., Roma, P. G., De Boever, P., Clément, G., Hargens, A. R., Loeppky, J. A., Evans, J. M., Peter Stein, T., Blaber, A. P., Van Loon, J. J. W. A., et al. (2012) · Planetary and Space Science · doi:10.1016/j.pss.2012.07.030 · Cited by 49
Metadata
- Authors
- Darquenne, C., Paiva, M., West, J. B., & Prisk, G. K.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1997-12-01
- Volume
- 83
- Issue
- 6
- Pages
- 2029-2036
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1690899404
- Cited by
- 66
- References
- 0
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of microgravity and hypergravity on deposition of 0.5- to 3-μm-diameter aerosol in the human lung. https://app.cochat.ai/papers/10.1152/jappl.1997.83.6.2029
- The paper
- Darquenne, C., Paiva, M., West, J. B., & Prisk, G. K. (1997). Effect of microgravity and hypergravity on deposition of 0.5- to 3-μm-diameter aerosol in the human lung. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1997.83.6.2029
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.