CoChat

Body composition by air-displacement plethysmography by using predicted and measured thoracic gas volumes

McCrory, Megan A., Molé, Paul A., Gomez, Terri D., Dewey, Kathryn G., Bernauer, Edmund M. · 1998 · Journal of Applied Physiology
Cited by 180

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The BOD POD, a new air-displacement plethysmograph for measuring human body composition, utilizes the inverse relationship between pressure and volume (Boyle’s law) to measure body volume directly. The quantity of air in the lungs during tidal breathing, the average thoracic gas volume (Vtg), is also measured by the BOD POD by using a standard plethysmographic technique. Alternatively, the BOD POD provides the use of a predicted Vtg (Vtg pred). The validity of using Vtg pred in place of measured Vtg (Vtg meas) to determine the percentage of body fat (%BF) was evaluated in 50 subjects (36 women, 14 men; ages 18–56 yr). There was no significant difference between Vtg meas and Vtg pred (mean difference ± SE, 53.5 ± 63.3 ml) nor in %BF by using Vtg meas vs. Vtg pred (0.2 ± 0.2 %BF). On an individual basis, %BF measured by using Vtg meas vs. Vtg pred differed within ±2.0% BF for 82% of the subjects; maximum differences were −2.9 to +3.0% BF. For comparison, data from 24 subjects who had undergone hydrostatic weighing were evaluated for the validity of using predicted vs. measured residual lung volume (Vr pred vs. Vr meas, respectively). Differences between Vr meas and Vr pred and in %BF calculated by using Vr meas vs. Vr pred were significant (187 ± 46 ml and 1.4 ± 0.3% BF, respectively; P < 0.001). On an individual basis, %BF determined by using Vr meas vs. Vr pred differed within ±2.0% BF for 46% of the subjects; maximum differences were −2.9 to +3.8% BF. With respect to %BF measured by air displacement, our findings support the use of Vtg pred for group mean comparisons and for purposes such as screening in young to middle-aged individuals. This contrasts with the use of Vr pred in hydrostatic weighing, which leads to significant errors in the estimation of %BF. Furthermore, although the use of Vtg pred has some application, determining Vtg meas is relatively simple in most cases. Therefore, we recommend that the use of Vtg meas remain as standard experimental and clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1998.84.4.1475

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 180

Metadata

Authors
McCrory, M. A., Molé, P. A., Gomez, T. D., Dewey, K. G., & Bernauer, E. M.
Venue
Journal of Applied Physiology
Published
1998-04-01
Volume
84
Issue
4
Pages
1475-1479
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2101703461
Cited by
180
References
1
FWCI
3.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.