The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Smaller lungs in women affect exercise hyperpnea
Abstract
We subjected 29 healthy young women (age: 27 ± 1 yr) with a wide range of fitness levels [maximal oxygen uptake (V˙o 2 max): 57 ± 6 ml ⋅ kg−1⋅ min−1; 35–70 ml ⋅ kg−1⋅ min−1] to a progressive treadmill running test. Our subjects had significantly smaller lung volumes and lower maximal expiratory flow rates, irrespective of fitness level, compared with predicted values for age- and height-matched men. The higher maximal workload in highly fit (V˙o 2 max> 57 ml ⋅ kg−1⋅ min−1, n = 14) vs. less-fit (V˙o 2 max< 56 ml ⋅ kg−1⋅ min−1, n = 15) women caused a higher maximal ventilation (V˙e) with increased tidal volume (Vt) and breathing frequency (f b) at comparable maximal Vt/vital capacity (VC). More expiratory flow limitation (EFL; 22 ± 4% of Vt) was also observed during heavy exercise in highly fit vs. less-fit women, causing higher end-expiratory and end-inspiratory lung volumes and greater usage of their maximum available ventilatory reserves. HeO 2(79% He-21% O 2) vs. room air exercise trials were compared (with screens added to equalize external apparatus resistance). HeO 2 increased maximal expiratory flow rates (20–38%) throughout the range of VC, which significantly reduced EFL during heavy exercise. When EFL was reduced with HeO 2, Vt, f b, andV˙e (+16 ± 2 l/min) were significantly increased during maximal exercise. However, in the absence of EFL (during room air exercise), HeO 2 had no effect onV˙e. We conclude that smaller lung volumes and maximal flow rates for women in general, and especially highly fit women, caused increased prevalence of EFL during heavy exercise, a relative hyperinflation, an increased reliance on f b, and a greater encroachment on the ventilatory “reserve.” Consequently, Vt andV˙e are mechanically constrained during maximal exercise in many fit women because the demand for high expiratory flow rates encroaches on the airways’ maximum flow-volume envelope.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These differences (mainly smaller lungs and maximal flow rates in women) may also affect dynamic volumes because fit women may suffer from expiratory flow limitation that induces an increase in EELV.132–134”
From Pathogenesis of hyperinflation in chronic obstructive pulmonary disease (2014) · cites this paper as [132]
Citations
Cites
Plum, F. (1960) · Archives of Neurology · doi:10.1001/archneur.1960.03840090124020 · Cited by 10,388
Lung Function Testing: Selection of Reference Values and Interpretative Strategies
(1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.5.1202 · Cited by 2,508
Changes in the normal maximal expiratory flow-volume curve with growth and aging.
Knudson, R. J., Lebowitz, M. D., Holberg, C. J., & Burrows, B. A. (1983) · PubMed · doi:10.1164/arrd.1983.127.6.725 · Cited by 1,913
Lung Function Testing: Selectionof reference Values and Interpretative Strategies
Miller, A. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/146.5_pt_1.1368b · Cited by 1,426
Maximal Oxygen Intake as an Objective Measure of Cardio-Respiratory Performance
TAYLOR, H. L., BUSKIRK, E. R., & Henschel, A. F. (1955) · Journal of Applied Physiology · doi:10.1152/jappl.1955.8.1.73 · Cited by 1,366
Weisman, I. M., & Zeballos, R. J. (1976) · American Heart Journal · doi:10.1016/s0002-8703(76)80065-8 · Cited by 1,217
Exercise : regulation and integration of multiple systems
Rowell, L. B., & Shepherd, J. T. (1996) · Medical Entomology and Zoology · Cited by 806
Normal standards for an incremental progressive cycle ergometer test.
Jones, N. L., Makrides, L., Hitchcock, C., Chypchar, T., & McCartney, N. (1985) · PubMed · doi:10.1164/arrd.1985.131.5.700 · Cited by 718
Respiratory muscle work compromises leg blood flow during maximal exercise
Harms, C. A., Babcock, M. A., McClaran, S. R., Pegelow, D. F., Nickele, G. A., Nelson, W. B., & Dempsey, J. A. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.5.1573 · Cited by 711
Self-citationThurlbeck, W. M. (1982) · Thorax · doi:10.1136/thx.37.8.564 · Cited by 610
Research works printed but not linked: 5
- Åstrand P. O., 1963, Acta Paediatr. Suppl., 147, 5
- Crapo R. O., 1982, Clin. Respir. Physiol., 18, 419
- Jones N. L., 1985, Am. Rev. Respir. Dis., 131, 700
- Knudson R. J., 1983, Am. Rev. Respir. Dis., 127, 725
- Mead J., 1980, Am. Rev. Respir. Dis., 121, 339
Cited by
Sorted by citations
Exercise-induced arterial hypoxemia
Dempsey, J. A., & Wagner, P. D. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.6.1997 · Cited by 658
Self-citationEffects of respiratory muscle work on cardiac output and its distribution during maximal exercise
Harms, C. A., Wetter, T. J., McClaran, S. R., Pegelow, D. F., Nickele, G. A., Nelson, W. B., Hanson, P., & Dempsey, J. A. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.2.609 · Cited by 469
Self-citationSex differences in respiratory function
LoMauro, A., & Aliverti, A. (2018) · Breathe · doi:10.1183/20734735.000318 · Cited by 356
Respiratory mechanics during exercise in endurance‐trained men and women
Guenette, J. A., Witt, J. D., McKenzie, D. C., Road, J. D., & Sheel, A. W. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.126466 · Cited by 247
HUNTER, S. K., S. ANGADI, S., BHARGAVA, A., HARPER, J., HIRSCHBERG, A. L., D. LEVINE, B., L. MOREAU, K., J. NOKOFF, N., STACHENFELD, N. S., & BERMON, S. (2023) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003300 · Cited by 241
Metadata
- Authors
- McClaran, S. R., Harms, C. A., Pegelow, D. F., & Dempsey, J. A.
- Affiliations
- University of Wisconsin–Madison (US)
- ORCID
- Dempsey, Jerome A.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1998-06-01
- Volume
- 84
- Issue
- 6
- Pages
- 1872-1881
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2156961077
- Cited by
- 238
- References
- 36
- Citations by year
- 2026: 4 · 2025: 10 · 2024: 12 · 2023: 11 · 2022: 9 · 2021: 11 · 2020: 10 · 2019: 10 · 2018: 11 · 2017: 9 · 2016: 5 · 2015: 10 · 2014: 12 · 2013: 15 · 2012: 11
- FWCI
- 9.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Heart, Lung, and Blood Institute (HL 15469)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
- Keywords
- sex differences in lung function, women, exercise hyperpnea, expiratory flow limitation, maximal expiratory flow, lung volume, ventilatory reserve, VO2max, treadmill running, helium-oxygen breathing, tidal volume, respiratory rate, respiratory mechanics
- MeSH terms
- Adolescent, Adult, Aerobiosis, Blood Gas Analysis, Blood Volume, Body Height, Female, Humans, Hydrogen-Ion Concentration, Lung, Lung Volume Measurements, Peak Expiratory Flow Rate, Potassium, Respiratory Function Tests, Vital Capacity, Exercise, Lactic Acid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review