Influence of volume dependency and timing of airway occlusions on the Hering-Breuer reflex in infants
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Both end-inspiratory (EIO) and end-expiratory (EEO) airway occlusions are used to calculate the strength of the Hering-Breuer inflation reflex (HBIR) in infants. However, the influence of the timing of such occlusions is unknown, as is the extent to which changes in volume within and above the tidal range affect this reflex. The purpose of this study was to compare both techniques and to evaluate the volume dependency of the HBIR in healthy, sleeping infants up to 1 yr of age. The strength of the HBIR was expressed as the ratio of expiratory or inspiratory time during EIO or EEO, respectively, to that recorded during spontaneous breathing, i.e., as the “inhibitory ratio” (IR). Paired measurements of the EIO and EEO in 26 naturally sleeping newborn and 15 lightly sedated infants at ∼1 yr showed no statistically significant differences in the IR according to technique: mean (95% CI) of the difference (EIO − EEO) being −0.02 (−0.17, 0.13) during the first week of life and 0.04 (−0.14, 0.22) at 1 yr. During tidal breathing, a volume threshold of ∼4 ml/kg was required to evoke the HBIR. Marked volume and age dependency were observed. In newborn infants, occlusions at ∼10 ml/kg during sighs always resulted in an IR > 4, whereas a similar response was only evoked at 25 ml/kg in older infants. Age-related changes in the volume threshold may reflect maturational changes in the control of breathing and respiratory mechanics throughout the first year of life.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Central pathways of pulmonary and lower airway vagal afferents.
Kubin, L., Alheid, G. F., Zuperku, E. J., & McCrimmon, D. R. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00252.2006 · Cited by 477
Piezo2 senses airway stretch and mediates lung inflation-induced apnoea
Nonomura, K., Woo, S.-H., Chang, R. B., Gillich, A., Qiu, Z., Francisco, A. G., Ranade, S. S., Liberles, S. D., & Patapoutian, A. (2017) · Nature · doi:10.1038/nature20793 · Cited by 428
Pontine Mechanisms of Respiratory Control
Dutschmann, M., & Dick, T. E. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100015 · Cited by 244
The effect of parental smoking on lung function and development during infancy
STOCKS, J., & DEZATEUX, C. (2003) · Respirology · doi:10.1046/j.1440-1843.2003.00478.x · Cited by 134
Self-citationDutschmann, M., Bautista, T. G., Mörschel, M., & Dick, T. E. (2014) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2014.02.009 · Cited by 39
Metadata
- Authors
- Rabbette, P. S., & Stocks, J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1998-12-01
- Volume
- 85
- Issue
- 6
- Pages
- 2033-2039
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1901898529
- Cited by
- 35
- References
- 1
- FWCI
- 0.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.