Dispersion of 0.5- to 2-μm aerosol in μG and hypergravity as a probe of convective inhomogeneity in the lung
The DOI matches its Crossref record.
Abstract
We used aerosol boluses to study convective gas mixing in the lung of four healthy subjects on the ground (1 G) and during short periods of microgravity (μG) and hypergravity (∼1.6 G). Boluses of 0.5-, 1-, and 2-μm-diameter particles were inhaled at different points in an inspiration from residual volume to 1 liter above functional residual capacity. The volume of air inhaled after the bolus [the penetration volume (V p)] ranged from 150 to 1,500 ml. Aerosol concentration and flow rate were continuously measured at the mouth. The dispersion, deposition, and position of the bolus in the expired gas were calculated from these data. For each particle size, both bolus dispersion and deposition increased with V p and were gravity dependent, with the largest dispersion and deposition occurring for the largest G level. Whereas intrinsic particle motions (diffusion, sedimentation, inertia) did not influence dispersion at shallow depths, we found that sedimentation significantly affected dispersion in the distal part of the lung (V p >500 ml). For 0.5-μm-diameter particles for which sedimentation velocity is low, the differences between dispersion in μG and 1 G likely reflect the differences in gravitational convective inhomogeneity of ventilation between μG and 1 G.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aerosol Deposition in Health and Disease
Darquenne, C. (2012) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2011.0916 · Cited by 452
Self-citationPhysiological, Pharmacokinetic, and Pharmacodynamic Changes in Space
Graebe, A., Schuck, E. L., Lensing, P., Putcha, L., & Derendorf, H. (2004) · The Journal of Clinical Pharmacology · doi:10.1177/0091270004267193 · Cited by 113
Linnarsson, D., Carpenter, J., Fubini, B., Gerde, P., Karlsson, L. L., Loftus, D. J., Prisk, G. K., Staufer, U., Tranfield, E. M., & van Westrenen, W. (2012) · Planetary and Space Science · doi:10.1016/j.pss.2012.05.023 · Cited by 95
Self-citationDeposition of inhaled particles in the human lung is more peripheral in lunar than in normal gravity
Darquenne, C., & Prisk, G. K. (2008) · European Journal of Applied Physiology · doi:10.1007/s00421-008-0766-y · Cited by 53
Self-citation(2008) · doi:10.1061/(asce)0893-1321(2008)21:4(266
Metadata
- Authors
- Darquenne, C., West, J. B., & Prisk, G. K.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1999-04-01
- Volume
- 86
- Issue
- 4
- Pages
- 1402-1409
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1922786190
- Cited by
- 54
- References
- 0
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dispersion of 0.5- to 2-μm aerosol in μG and hypergravity as a probe of convective inhomogeneity in the lung. https://app.cochat.ai/papers/10.1152/jappl.1999.86.4.1402
- The paper
- Darquenne, C., West, J. B., & Prisk, G. K. (1999). Dispersion of 0.5- to 2-μm aerosol in μG and hypergravity as a probe of convective inhomogeneity in the lung. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1999.86.4.1402
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.