The DOI matches its Crossref record.
Comparative respiratory system mechanics in rodents
Abstract
Because of the wide utilization of rodents as animal models in respiratory research and the limited data on measurements of respiratory input impedance (Zrs) in small animals, we measured Zrs between 0.25 and 9.125 Hz at different levels (0–7 hPa) of positive end-expiratory pressure (PEEP) in mice, rats, guinea pigs, and rabbits using a computer-controlled small-animal ventilator (Schuessler TF and Bates JHT, IEEE Trans Biomed Eng 42: 860–866, 1995). Zrs was fitted with a model, including a Newtonian resistance (R) and inertance in series with a constant-phase tissue compartment characterized by tissue damping (Gti) and elastance (Hti) parameters. Inertance was negligible in all cases. R, Gti, and Hti were normalized to body weight, yielding normalized R, Gti, and Hti (NHti), respectively. Normalized R tended to decrease slightly with PEEP and increased with animal size. Normalized Gti had a minimal dependence on PEEP. NHti decreased with increasing PEEP, reaching a minimum at ∼5 hPa in all species except mice. NHti was also higher in mice and rabbits compared with guinea pigs and rats at low PEEPs, which we conclude is probably due to a relatively smaller air space volume in mice and rabbits. Our data also suggest that smaller rodents have proportionately wider airways than do larger animals. We conclude that a detailed, comparative study of respiratory system mechanics shows some evidence of structural differences among the lungs of various species but that, in general, rodent lungs obey scaling laws similar to those described in other species.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Technical standards for respiratory oscillometry
King, G. G., Bates, J., Berger, K. I., Calverley, P., de Melo, P. L., Dellacà, R. L., Farré, R., Hall, G. L., Ioan, I., Irvin, C. G., et al. (2020) · European Respiratory Journal · doi:10.1183/13993003.00753-2019 · Cited by 756
Self-citationMeasuring the lung function in the mouse: the challenge of size
Irvin, C. G., & Bates, J. H. (2003) · Respiratory Research · doi:10.1186/rr199 · Cited by 407
Self-citationZosky, G. R., & Sly, P. D. (2007) · Clinical & Experimental Allergy · doi:10.1111/j.1365-2222.2007.02740.x · Cited by 298
Tumor Necrosis Factor–α Overexpression in Lung Disease: A Single Cause behind a Complex Phenotype
Lundblad, L. K. A., Thompson-Figueroa, J., Leclair, T., Sullivan, M. J., Poynter, M. E., Irvin, C. G., & Bates, J. H. T. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200410-1349oc · Cited by 261
Self-citationPulmonary Exposure to Particles during Pregnancy Causes Increased Neonatal Asthma Susceptibility
Fedulov, A. V., Leme, A., Yang, Z., Dahl, M., Lim, R., Mariani, T. J., & Kobzik, L. (2008) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/rcmb.2007-0124oc · Cited by 204
Metadata
- Authors
- Gomes, R. F. M., Shen, X., Ramchandani, R., Tepper, R. S., & Bates, J. H. T.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2000-09-01
- Volume
- 89
- Issue
- 3
- Pages
- 908-916
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2157022248
- Cited by
- 178
- References
- 0
- FWCI
- 6.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparative respiratory system mechanics in rodents. https://app.cochat.ai/papers/10.1152/jappl.2000.89.3.908
- The paper
- Gomes, R. F. M., Shen, X., Ramchandani, R., Tepper, R. S., & Bates, J. H. T. (2000). Comparative respiratory system mechanics in rodents. Journal of Applied Physiology. https://doi.org/10.1152/jappl.2000.89.3.908
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.