Neurocirculatory consequences of intermittent asphyxia in humans
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We examined the neurocirculatory and ventilatory responses to intermittent asphyxia (arterial O 2 saturation = 79–85%, end-tidal Pco 2 =3–5 Torr above eupnea) in seven healthy humans during wakefulness. The intermittent asphyxia intervention consisted of 20-s asphyxic exposures alternating with 40-s periods of room-air breathing for a total of 20 min. Minute ventilation increased during the intermittent asphyxia period (14.2 ± 2.0 l/min in the final 5 min of asphyxia vs. 7.5 ± 0.4 l/min in baseline) but returned to the baseline level within 2 min after completion of the series of asphyxic exposures. Muscle sympathetic nerve activity increased progressively, reaching 175 ± 12% of baseline in the final 5 min of the intervention. Unlike ventilation, sympathetic activity remained elevated for at least 20 min after removal of the chemical stimuli (150 ± 10% of baseline in the last 5 min of the recovery period). Intermittent asphyxia caused a small, but statistically significant, increase in heart rate (64 ± 4 beats/min in the final 5 min of asphyxia vs. 61 ± 4 beats/min in baseline); however, this increase was not sustained after the return to room-air breathing. These data demonstrate that relatively short-term exposure to intermittent asphyxia causes sympathetic activation that persists after removal of the chemical stimuli. This carryover effect provides a potential mechanism whereby intermittent asphyxia during sleep could lead to chronic sympathetic activation in patients with sleep apnea syndrome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Somatosensory, proprioceptive, and sympathetic activity in human peripheral nerves
Vallbo, A. B., Hagbarth, K. E., Torebjork, H. E., & Wallin, B. G. (1979) · Physiological Reviews · doi:10.1152/physrev.1979.59.4.919 · Cited by 1,507 · cited 1×
“Postganglionic muscle sympathetic nerve activity in the right peroneal nerve was recorded directly by using the microneurography technique (22).”
Method
Cited by
Pathophysiology of Sleep Apnea
Dempsey, J. A., Veasey, S. C., Morgan, B. J., & O'Donnell, C. P. (2010) · Physiological Reviews · doi:10.1152/physrev.00043.2008 · Cited by 2,243
Self-citationObstructive sleep apnoea syndrome – an oxidative stress disorder
Lavie, L. (2003) · Sleep Medicine Reviews · doi:10.1053/smrv.2002.0261 · Cited by 993
Sleep Apnea and Cardiovascular Disease
LEUNG, R. S. T., & DOUGLAS BRADLEY, T. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.12.2107045 · Cited by 649
Endothelial Function in Obstructive Sleep Apnea and Response to Treatment
Ip, M. S. M., Tse, H.-F., Lam, B., Tsang, K. W. T., & Lam, W.-K. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200306-767oc · Cited by 615
Exposure to hypoxia produces long-lasting sympathetic activation in humans
Xie, A., Skatrud, J. B., Puleo, D. S., & Morgan, B. J. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.4.1555 · Cited by 307
Self-citation
Metadata
- Authors
- Xie, A., Skatrud, J. B., Crabtree, D. C., Puleo, D. S., Goodman, B. M., & Morgan, B. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2000-10-01
- Volume
- 89
- Issue
- 4
- Pages
- 1333-1339
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2400072435
- Cited by
- 108
- References
- 1
- FWCI
- 0.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.