Lower limb skeletal muscle mass: development of dual-energy X-ray absorptiometry prediction model
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Although magnetic resonance imaging (MRI) can accurately measure lower limb skeletal muscle (SM) mass, this method is complex and costly. A potential practical alternative is to estimate lower limb SM with dual-energy X-ray absorptiometry (DXA). The aim of the present study was to develop and validate DXA-SM prediction equations. Identical landmarks (i.e., inferior border of the ischial tuberosity) were selected for separating lower limb from trunk. Lower limb SM was measured by MRI, and lower limb fat-free soft tissue was measured by DXA. A total of 207 adults (104 men and 103 women) were evaluated [age 43 ± 16 (SD) yr, body mass index (BMI) 24.6 ± 3.7 kg/m 2]. Strong correlations were observed between lower limb SM and lower limb fat-free soft tissue ( R 2 = 0.89, P < 0.001); age and BMI were small but significant SM predictor variables. In the cross-validation sample, the differences between MRI-measured and DXA-predicted SM mass were small (−0.006 ± 1.07 and −0.016 ± 1.05 kg) for two different proposed prediction equations, one with fat-free soft tissue and the other with added age and BMI as predictor variables. DXA-measured lower limb fat-free soft tissue, along with other easily acquired measures, can be used to reliably predict lower limb skeletal muscle mass.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Dual-energy X-ray absorptiometry body composition model: review of physical concepts
Pietrobelli, A., Formica, C., Wang, Z., & Heymsfield, S. B. (1996) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1996.271.6.e941 · Cited by 594
Self-citationOrgan-tissue mass measurement allows modeling of REE and metabolically active tissue mass
Gallagher, D., Belmonte, D., Deurenberg, P., Wang, Z., Krasnow, N., Pi-Sunyer, F. X., & Heymsfield, S. B. (1998) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1998.275.2.e249 · Cited by 470
Self-citation
Cited by
Joyner, M. J., & Casey, D. P. (2015) · Physiological Reviews · doi:10.1152/physrev.00035.2013 · Cited by 833
Total-body skeletal muscle mass: Estimation by a new dual-energy X-ray absorptiometry method
Kim, J., Wang, Z., Heymsfield, S. B., Baumgartner, R. N., & Gallagher, D. (2002) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/76.2.378 · Cited by 737
Self-citationLassek, W. D., & Gaulin, S. J. C. (2009) · Evolution and Human Behavior · doi:10.1016/j.evolhumbehav.2009.04.002 · Cited by 397
Breen, L., Stokes, K. A., Churchward-Venne, T. A., Moore, D. R., Baker, S. K., Smith, K., Atherton, P. J., & Phillips, S. M. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2013-1502 · Cited by 395
Weinheimer, E. M., Sands, L. P., & Campbell, W. W. (2010) · Nutrition Reviews · doi:10.1111/j.1753-4887.2010.00298.x · Cited by 391
Metadata
- Authors
- Shih, R., Wang, Z., Heo, M., Wang, W., & Heymsfield, S. B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2000-10-01
- Volume
- 89
- Issue
- 4
- Pages
- 1380-1386
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2166269531
- Cited by
- 101
- References
- 3
- FWCI
- 1.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.