Validity of NIR spectroscopy for quantitatively measuring muscle oxidative metabolic rate in exercise
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to examine the validity of the quantitative measurement of muscle oxidative metabolism in exercise by near-infrared continuous-wave spectroscopy (NIRcws). Twelve male subjects performed two bouts of dynamic handgrip exercise, once for the NIRcws measurement and once for the 31 P-magnetic resonance spectroscopy (MRS) measurement as a standard measure. The resting muscle metabolic rate (RMRmus) was independently measured by 31 P-MRS during 15 min of arterial occlusion at rest. During the first exercise bout, the quantitative value of muscle oxidative metabolic rate at 30 s postexercise was evaluated from the ratio of the rate of oxyhemoglobin/myoglobin decline measured by NIRcws during arterial occlusion 30 s after exercise and the rate at rest. Therefore, the absolute values of muscle oxidative metabolic rate at 30 s after exercise [V˙o 2NIR(30)] was calculated from this ratio multiplied by RMRmus. During the second exercise bout, creatine phosphate (PCr) resynthesis rate was measured by 31 P-MRS at 30 s postexercise [Q(30)] under the same conditions but without arterial occlusion postexercise. To determine the validity of NIRcws, V˙o 2NIR(30) was compared with Q(30). There was a significant correlation betweenV˙o 2NIR(30), which ranged between 0.018 and 0.187 mM ATP/s, and Q(30), which ranged between 0.041 and 0.209 mM ATP/s ( r = 0.965, P < 0.001). This result supports the application of NIRcws to quantitatively evaluate muscle oxidative metabolic rate in exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669 · cited 1×
“Over the past several years, many more groups have applied this technique (3, 10, 11, 15, 18, 23, 29).”
MethodRecovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Self-citationArnold, D. L., Matthews, P. M., & Radda, G. K. (1984) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910010303 · Cited by 442
McCully, K. K., Fielding, R. A., Evans, W. J., Leigh, J. S., & Posner, J. D. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.75.2.813 · Cited by 288 · cited 2×
“Postexercise PCr resynthesis rate (Q) measured by (31)P-MRS has been recognized as one of the most reliable parameters for quantifying the rate of oxidative ATP production (7, 19, 21, 25).”
MethodResultMahler, M. (1985) · The Journal of general physiology · doi:10.1085/jgp.86.1.135 · Cited by 234 · cited 1×
“PCr monoexponentially recovers during the recovery period (22), and the PCr concentration can be described by the following equation”
BackgroundBelardinelli, R., Barstow, T. J., Porszasz, J., & Wasserman, K. (1995) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00634377 · Cited by 213
Kemp, G. J., Thompson, C. H., Barnes, P. R. J., & Radda, G. K. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310303 · Cited by 116 · cited 1×
“Some studies achieved a much better time resolution in which the initial Q values were measured directly from the changes in PCr concentrations between successive time points (5, 20); however, it was pointed out that obvious random error occurred in the case of Q calculated in 10 s Fig.”
Method
Cited by
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Grassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
“The validity of the approach was subsequently confirmed.(102) The limitations are represented by the fact that the NIRS measurements need to be carried out in ischemic conditions and that the measurements are possible only in the recovery phase following exercise, during which _ VO2 rapidly decreases.”
BackgroundHamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Self-citationKemp, G. J., Meyerspeer, M., & Moser, E. (2007) · NMR in Biomedicine · doi:10.1002/nbm.1192 · Cited by 312
Ryan, T. E., Southern, W. M., Reynolds, M. A., & McCully, K. K. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00835.2013 · Cited by 192
Metadata
- Authors
- Sako, T., Hamaoka, T., Higuchi, H., Kurosawa, Y., & Katsumura, T.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2001-01-01
- Volume
- 90
- Issue
- 1
- Pages
- 338-344
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2212493890
- Cited by
- 132
- References
- 7
- FWCI
- 23.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validity of NIR spectroscopy for quantitatively measuring muscle oxidative metabolic rate in exercise. https://app.cochat.ai/papers/10.1152/jappl.2001.90.1.338
- The paper
- Sako, T., Hamaoka, T., Higuchi, H., Kurosawa, Y., & Katsumura, T. (2001). Validity of NIR spectroscopy for quantitatively measuring muscle oxidative metabolic rate in exercise. Journal of Applied Physiology. https://doi.org/10.1152/jappl.2001.90.1.338
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.