CoChat

Chamber properties from transmitral flow: prediction of average and passive left ventricular diastolic stiffness

Lisauskas, Jennifer B., Singh, Jasvindar, Bowman, Andrew W., Kovács, Sándor J. · 2001 · Journal of Applied Physiology
Cited by 85

The DOI matches its Crossref record.

Abstract

A chamber stiffness ( K LV)-transmitral flow (E-wave) deceleration time relation has been invasively validated in dogs with the use of average stiffness [(ΔP/ΔV)avg]. K LV is equivalent to k E, the (E-wave) stiffness of the parameterized diastolic filling model. Prediction and validation of 1) (ΔP/ΔV)avg in terms of k E, 2) early rapid-filling stiffness [(ΔP/ΔV)E] in terms of k E, and 3) passive (postdiastasis) chamber stiffness [(ΔP/ΔV)PD] from A waves in terms of the stiffness parameter for the Doppler A wave ( k A) have not been achieved. Simultaneous micromanometric left ventricular (LV) pressure (LVP) and transmitral flow from 131 subjects were analyzed. (ΔP)avg and (ΔV)avg utilized the minimum LVP-LV end-diastolic pressure interval. (ΔP/ΔV)E utilized ΔP and ΔV from minimum LVP to E-wave termination. (ΔP/ΔV)PD utilized atrial systolic ΔP and ΔV. E- and A-wave analysis generated k E and k A. For all subjects, noninvasive-invasive relations yielded the following equations: k E= 1,401 · (ΔP/ΔV)avg+ 59.2 ( r = 0.84) and k E= 229.0 · (ΔP/ΔV)E+ 112 ( r= 0.80). For subjects with diastasis ( n = 113), k A= 1,640 · (ΔP/ΔV)PD− 8.40 ( r = 0.89). As predicted, k A showed excellent correlation with (ΔP/ΔV)PD; k E correlated highly with (ΔP/ΔV)avg. In vivo validation of average, early, and passive chamber stiffness facilitates quantitative, noninvasive diastolic function assessment from transmitral flow.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.2001.91.1.154

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 85

Metadata

Authors
Lisauskas, J. B., Singh, J., Bowman, A. W., & Kovács, S. J.
Venue
Journal of Applied Physiology
Published
2001-07-01
Volume
91
Issue
1
Pages
154-162
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2180535724
Cited by
85
References
0
FWCI
2.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Chamber properties from transmitral flow: prediction of average and passive left ventricular diastolic stiffness. https://app.cochat.ai/papers/10.1152/jappl.2001.91.1.154
The paper
Lisauskas, J. B., Singh, J., Bowman, A. W., & Kovács, S. J. (2001). Chamber properties from transmitral flow: prediction of average and passive left ventricular diastolic stiffness. Journal of Applied Physiology. https://doi.org/10.1152/jappl.2001.91.1.154

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.