The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Human breath isoprene and its relation to blood cholesterol levels: new measurements and modeling
Abstract
Numerous publications have described measurements of breath isoprene in humans, and there has been a hope that breath isoprene analyses could be a noninvasive diagnostic tool to assess blood cholesterol levels or cholesterol synthesis rate. However, significant analytic problems in breath isoprene analysis and variability in isoprene levels with age, exercise, diet, etc., have limited the usefulness of these measurements. Here, we have applied proton transfer reaction-mass spectrometry to this problem, allowing on-line detection of breath isoprene. We show that breath isoprene concentration increases within a few seconds after exercise is started as a result of a rapid increase in heart rate and then reaches a lower steady state when breath rate stabilizes. Additional experiments demonstrated that increases in heart rate associated with standing after reclining or sleeping are associated with increased breath isoprene concentrations. An isoprene gas-exchange model was developed and shows excellent fit to breath isoprene levels measured during exercise. In a preliminary experiment, we demonstrated that atorvastatin therapy leads to a decrease in serum cholesterol and low-density-lipoprotein levels and a parallel decrease in breath isoprene levels. This work suggests that there is constant endogenous production of isoprene during the day and night and reaffirms the possibility that breath isoprene can be a noninvasive marker of cholesterologenesis if care is taken to measure breath isoprene under standard conditions at constant heart rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lindinger, W., Hansel, A., & Jordan, A. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00281-4 · Cited by 1,615
Self-citationAggressive Lipid-Lowering Therapy Compared with Angioplasty in Stable Coronary Artery Disease
Pitt, B., Waters, D., Brown, W. V., van Boven, A. J., Schwartz, L., Title, L. M., Eisenberg, D., Shurzinske, L., & McCormick, L. S. (1999) · New England Journal of Medicine · doi:10.1056/nejm199907083410202 · Cited by 946
Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level
Hansel, A., Jordan, A., Holzinger, R., Prazeller, P., Vogel, W., & Lindinger, W. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04294-u · Cited by 727
Self-citationHuman Breath Emissions of VOCs
Fenske, J. D., & Paulson, S. E. (1999) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1999.10463831 · Cited by 302
Selected ion flow tube: a technique for quantitative trace gas analysis of air and breath
Španěl, P., & Smith, D. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02523843 · Cited by 229
Evidence for diurnal periodicity in human cholesterol synthesis.
Jones, P., & Schoeller, D. (1990) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)42835-4 · Cited by 179
Plasma mevalonate as a measure of cholesterol synthesis in man.
Parker, T. S., McNamara, D. J., Brown, C. D., Kolb, R., Ahrens, E. H., Alberts, A. W., Tobert, J., Chen, J., & De Schepper, P. J. (1984) · Journal of Clinical Investigation · doi:10.1172/jci111495 · Cited by 167
Effect of regulating cholesterol biosynthesis on breath isoprene excretion in men
Stone, B. G., Besse, T. J., Duane, W. C., Dean Evans, C., & DeMaster, E. G. (1993) · Lipids · doi:10.1007/bf02535990 · Cited by 161
Jordan, A., Hansel, A., Holzinger, R., & Lindinger, W. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04236-e · Cited by 136
Self-citationTaucher, J., Hansel, A., Jordan, A., & Lindinger, W. (1996) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf960640e · Cited by 133
Self-citation
Cited by
Structural and Chemical Biology of Terpenoid Cyclases
Christianson, D. W. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00287 · Cited by 1,223
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
“Originally, it was thought that this increase is just due to an increase of cardiac output [69].”
BackgroundHuman exhaled air analytics: biomarkers of diseases
Buszewski, B., Kęsy, M., Ligor, T., & Amann, A. (2007) · Biomedical Chromatography · doi:10.1002/bmc.835 · Cited by 792
Proton-Transfer Reaction Mass Spectrometry
Blake, R. S., Monks, P. S., & Ellis, A. M. (2009) · Chemical Reviews · doi:10.1021/cr800364q · Cited by 745
Noninvasive detection of lung cancer by analysis of exhaled breath
Bajtarevic, A., Ager, C., Pienz, M., Klieber, M., Schwarz, K., Ligor, M., Ligor, T., Filipiak, W., Denz, H., Fiegl, M., et al. (2009) · BMC Cancer · doi:10.1186/1471-2407-9-348 · Cited by 597
Review—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Das, S., & Pal, M. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67a6 · Cited by 466
Breath Sensors for Health Monitoring
Güntner, A. T., Abegg, S., Königstein, K., Gerber, P. A., Schmidt-Trucksäss, A., & Pratsinis, S. E. (2019) · ACS Sensors · doi:10.1021/acssensors.8b00937 · Cited by 410
Advances in Electronic-Nose Technologies Developed for Biomedical Applications
Wilson, A. D., & Baietto, M. (2011) · Sensors · doi:10.3390/s110101105 · Cited by 400
A review of breath analysis for diagnosis of human health
Kim, K.-H., Jahan, S. A., & Kabir, E. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.09.013 · Cited by 345
Volatile Organic Compounds in Exhaled Breath as Fingerprints of Lung Cancer, Asthma and COPD
Ratiu, I. A., Ligor, T., Bocos-Bintintan, V., Mayhew, C. A., & Buszewski, B. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm10010032 · Cited by 320
Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications
Lourenço, C., & Turner, C. (2014) · Metabolites · doi:10.3390/metabo4020465 · Cited by 314
Drabińska, N., Flynn, C., Ratcliffe, N., Belluomo, I., Myridakis, A., Gould, O., Fois, M., Smart, A., Devine, T., & Costello, B. D. L. (2021) · Journal of Breath Research · doi:10.1088/1752-7163/abf1d0 · Cited by 288
Lung cancer detection by proton transfer reaction mass-spectrometric analysis of human breath gas
Wehinger, A., Schmid, A., Mechtcheriakov, S., Ledochowski, M., Grabmer, C., Gastl, G. A., & Amann, A. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2007.05.012 · Cited by 280
Isoprene and acetone concentration profiles during exercise on an ergometer
King, J., Kupferthaler, A., Unterkofler, K., Koc, H., Teschl, S., Teschl, G., Miekisch, W., Schubert, J., Hinterhuber, H., & Amann, A. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027006 · Cited by 278
Buhr, K., van Ruth, S., & Delahunty, C. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00896-5 · Cited by 271
Ligor, M., Ligor, T., Bajtarevic, A., Ager, C., Pienz, M., Klieber, M., Denz, H., Fiegl, M., Hilbe, W., Weiss, W., et al. (2009) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2009.133 · Cited by 262
Maity, A., Raychaudhuri, A. K., & Ghosh, B. (2019) · Scientific Reports · doi:10.1038/s41598-019-43961-6 · Cited by 200
Metadata
- Authors
- Karl, T., Prazeller, P., Mayr, D., Jordan, A., Rieder, J., Fall, R., & Lindinger, W.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2001-08-01
- Volume
- 91
- Issue
- 2
- Pages
- 762-770
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2257061691
- Cited by
- 264
- References
- 15
- FWCI
- 5.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.