The DOI matches its Crossref record.
Biomechanical response to acupuncture needling in humans
Abstract
During acupuncture treatments, acupuncture needles are manipulated to elicit the characteristic “de qi” reaction widely viewed as essential to acupuncture's therapeutic effect. De qi has a biomechanical component, “needle grasp,” which we have quantified by measuring the force necessary to pull an acupuncture needle out of the skin (pullout force) in 60 human subjects. We hypothesized that pullout force is greater with both bidirectional needle rotation (BI) and unidirectional rotation (UNI) than no rotation (NO). Acupuncture needles were inserted, manipulated, and pulled out by using a computer-controlled acupuncture needling instrument at eight acupuncture points and eight control points. We found 167 and 52% increases in mean pullout force with UNI and BI, respectively, compared with NO (repeated-measures ANOVA, P < 0.001). Pullout force was on average 18% greater at acupuncture points than at control points ( P < 0.001). Needle grasp is therefore a measurable biomechanical phenomenon associated with acupuncture needle manipulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Relationship of acupuncture points and meridians to connective tissue planes
Langevin, H. M., & Yandow, J. A. (2002) · The Anatomical Record · doi:10.1002/ar.10185 · Cited by 543
Self-citationLangevin, H. M., Churchill, D. L., & Cipolla, M. J. (2001) · The FASEB Journal · doi:10.1096/fj.01-0015hyp · Cited by 477
Self-citationCherkin, D. C., Sherman, K. J., Avins, A. L., Erro, J. H., Ichikawa, L., Barlow, W. E., Delaney, K., Hawkes, R., Hamilton, L., Pressman, A., et al. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.65 · Cited by 438
Evidence of Connective Tissue Involvement in Acupuncture
Langevin, H. M., Churchill, D. L., Wu, J., Badger, G. J., Yandow, J. A., Fox, J. R., & Krag, M. H. (2002) · The FASEB Journal · doi:10.1096/fj.01-0925fje · Cited by 311
Self-citationAcupuncture Analgesia: I. The Scientific Basis
Wang, S.-M., Kain, Z. N., & White, P. (2008) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000277493.42335.7b · Cited by 275
Metadata
- Authors
- Langevin, H. M., Churchill, D. L., Fox, J. R., Badger, G. J., Garra, B. S., & Krag, M. H.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2001-12-01
- Volume
- 91
- Issue
- 6
- Pages
- 2471-2478
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2151672065
- Cited by
- 249
- References
- 0
- FWCI
- 12.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biomechanical response to acupuncture needling in humans. https://app.cochat.ai/papers/10.1152/jappl.2001.91.6.2471
- The paper
- Langevin, H. M., Churchill, D. L., Fox, J. R., Badger, G. J., Garra, B. S., & Krag, M. H. (2001). Biomechanical response to acupuncture needling in humans. Journal of Applied Physiology. https://doi.org/10.1152/jappl.2001.91.6.2471
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.