Estimating changes in mean body temperature for humans during exercise using core and skin temperatures is inaccurate even with a correction factor
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Changes in mean body temperature (ΔT̄b) estimated by the traditional two-compartment model of “core” and “shell” temperatures and an adjusted two-compartment model incorporating a correction factor were compared with values derived by whole body calorimetry. Sixty participants (31 men, 29 women) cycled at 40% of peak O 2 consumption for 60 or 90 min in the Snellen calorimeter at 24 or 30°C. The core compartment was represented by esophageal, rectal (T re), and aural canal temperature, and the shell compartment was represented by a 12-point mean skin temperature (T̄sk). Using T re and conventional core-to-shell weightings ( X) of 0.66, 0.79, and 0.90, mean ΔT̄b estimation error (with 95% confidence interval limits in parentheses) for the traditional model was −95.2% (−83.0, −107.3) to −76.6% (−72.8, −80.5) after 10 min and −47.2% (−40.9, −53.5) to −22.6% (−14.5, −30.7) after 90 min. Using T re, X = 0.80, and a correction factor ( X 0) of 0.40, mean ΔT̄b estimation error for the adjusted model was +9.5% (+16.9, +2.1) to −0.3% (+11.9, −12.5) after 10 min and +15.0% (+27.2, +2.8) to −13.7% (−4.2, −23.3) after 90 min. Quadratic analyses of calorimetry ΔT̄b data was subsequently used to derive best-fitting values of X for both models and X 0 for the adjusted model for each measure of core temperature. The most accurate model at any time point or condition only accounted for 20% of the variation observed in ΔT̄b for the traditional model and 56% for the adjusted model. In conclusion, throughout exercise the estimation of ΔT̄b using any measure of core temperature together with mean skin temperature irrespective of weighting is inaccurate even with a correction factor customized for the specific conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Individualized model of human thermoregulation for the simulation of heat stress response
Havenith, G. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.5.1943 · Cited by 299 · cited 1×
“Typical core-to-shell ratios range from 9:1 or 4:1 for a hot environment (28, 29) to 2:1 for a moderate or cold environment (4, 9, 15, 19, 35).”
Background
Cited by
Sawka, M. N., Leon, L. R., Montain, S. J., & Sonna, L. A. (2011) · Comprehensive Physiology · doi:10.1002/cphy.c100082 · Cited by 470
Considerations for the measurement of core, skin and mean body temperatures
Taylor, N. A. S., Tipton, M. J., & Kenny, G. P. (2014) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2014.10.006 · Cited by 420
Self-citationThermometry, Calorimetry, and Mean Body Temperature during Heat Stress
Kenny, G. P., & Jay, O. (2013) · Comprehensive Physiology · doi:10.1002/cphy.c130011 · Cited by 277
Self-citationMarginal effects of a large caffeine dose on heat balance during exercise‐heat stress
Ely, B. R., Ely, M. R., & Cheuvront, S. N. (2011) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.21.1.65 · Cited by 33
“Any remaining error compared with calorimetry (Jay et al., 2007) was assumed equal between trials.”
Method
Metadata
- Authors
- Jay, O., Reardon, F. D., Webb, P., DuCharme, M. B., Ramsay, T., Nettlefold, L., & Kenny, G. P.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2007-08
- Volume
- 103
- Issue
- 2
- Pages
- 443-451
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2128231432
- Cited by
- 79
- References
- 1
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimating changes in mean body temperature for humans during exercise using core and skin temperatures is inaccurate even with a correction factor. https://app.cochat.ai/papers/10.1152/japplphysiol.00117.2007
- The paper
- Jay, O., Reardon, F. D., Webb, P., DuCharme, M. B., Ramsay, T., Nettlefold, L., & Kenny, G. P. (2007). Estimating changes in mean body temperature for humans during exercise using core and skin temperatures is inaccurate even with a correction factor. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00117.2007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.