Decomposition of indwelling EMG signals
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Decomposition of indwelling electromyographic (EMG) signals is challenging in view of the complex and often unpredictable behaviors and interactions of the action potential trains of different motor units that constitute the indwelling EMG signal. These phenomena create a myriad of problem situations that a decomposition technique needs to address to attain completeness and accuracy levels required for various scientific and clinical applications. Starting with the maximum a posteriori probability classifier adapted from the original precision decomposition system (PD I) of LeFever and De Luca ( 25 , 26 ), an artificial intelligence approach has been used to develop a multiclassifier system (PD II) for addressing some of the experimentally identified problem situations. On a database of indwelling EMG signals reflecting such conditions, the fully automatic PD II system is found to achieve a decomposition accuracy of 86.0% despite the fact that its results include low-amplitude action potential trains that are not decomposable at all via systems such as PD I. Accuracy was established by comparing the decompositions of indwelling EMG signals obtained from two sensors. At the end of the automatic PD II decomposition procedure, the accuracy may be enhanced to nearly 100% via an interactive editor, a particularly significant fact for the previously indecomposable trains.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Behaviour of human motor units in different muscles during linearly varying contractions
de Luca, C. J., LeFever, R. S., McCue, M. P., & Xenakis, A. P. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014293 · Cited by 719
Firing rates of motor units in human vastus lateralis muscle during fatiguing isometric contractions
Adam, A., & De Luca, C. J. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01344.2004 · Cited by 219
Cited by
Multi-channel intramuscular and surface EMG decomposition by convolutive blind source separation
Negro, F., Muceli, S., Castronovo, A. M., Holobar, A., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026027 · Cited by 647
Holobar, A., Minetto, M. A., & Farina, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016008 · Cited by 400
“Reliable identification of MU behaviour is a long-standing problem that has been addressed in several previous studies (Nawab et al 2008, 2010, Holobar et al 2010, McGill and Marateb 2011).”
BackgroundHigh-yield decomposition of surface EMG signals
Nawab, S. H., Chang, S.-S., & De Luca, C. J. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.11.092 · Cited by 370
Self-citationEstimating motor unit discharge patterns from high-density surface electromyogram.
Holobar, A., Farina, D., Gazzoni, M., Merletti, R., & Zazula, D. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.10.160 · Cited by 318
A Novel Framework Based on FastICA for High Density Surface EMG Decomposition
Chen, M., & Zhou, P. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2412038 · Cited by 260
Metadata
- Authors
- Nawab, S. H., Wotiz, R. P., & De Luca, C. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2008-08
- Volume
- 105
- Issue
- 2
- Pages
- 700-710
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2069243622
- Cited by
- 86
- References
- 2
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Decomposition of indwelling EMG signals. https://app.cochat.ai/papers/10.1152/japplphysiol.00170.2007
- The paper
- Nawab, S. H., Wotiz, R. P., & De Luca, C. J. (2008). Decomposition of indwelling EMG signals. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00170.2007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.