The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
The fastest runner on artificial legs: different limbs, similar function?
Abstract
The recent competitive successes of a bilateral, transtibial amputee sprint runner who races with modern running prostheses has triggered an international controversy regarding the relative function provided by his artificial limbs. Here, we conducted three tests of functional similarity between this amputee sprinter and competitive male runners with intact limbs: the metabolic cost of running, sprinting endurance, and running mechanics. Metabolic and mechanical data, respectively, were acquired via indirect calorimetry and ground reaction force measurements during constant-speed, level treadmill running. First, we found that the mean gross metabolic cost of transport of our amputee sprint subject (174.9 ml O 2·kg−1·km−1; speeds: 2.5–4.1 m/s) was only 3.8% lower than mean values for intact-limb elite distance runners and 6.7% lower than for subelite distance runners but 17% lower than for intact-limb 400-m specialists [210.6 (SD 13.2) ml O 2·kg−1·km−1]. Second, the speeds that our amputee sprinter maintained for six all-out, constant-speed trials to failure (speeds: 6.6–10.8 m/s; durations: 2–90 s) were within 2.2 (SD 0.6)% of those predicted for intact-limb sprinters. Third, at sprinting speeds of 8.0, 9.0, and 10.0 m/s, our amputee subject had longer foot-ground contact times [+14.7 (SD 4.2)%], shorter aerial [−26.4 (SD 9.9)%] and swing times [−15.2 (SD 6.9)%], and lower stance-averaged vertical forces [−19.3 (SD 3.1)%] than intact-limb sprinters [top speeds = 10.8 vs. 10.8 (SD 0.6) m/s]. We conclude that running on modern, lower-limb sprinting prostheses appears to be physiologically similar but mechanically different from running with intact limbs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energetics of running: a new perspective
Kram, R., & Taylor, C. R. (1990) · Nature · doi:10.1038/346265a0 · Cited by 821
Self-citationRunning economy of elite male and elite female runners
DANIELS, J., & DANIELS, N. (1992) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199204000-00015 · Cited by 345
Balance and kinetics of anaerobic energy release during strenuous exercise in man
Margaria, R., Cerretelli, P., & Mangili, F. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.4.623 · Cited by 150
Cited by
The Importance of Muscular Strength in Athletic Performance
Suchomel, T. J., Nimphius, S., & Stone, M. H. (2016) · Sports Medicine · doi:10.1007/s40279-016-0486-0 · Cited by 1,466
Technical Ability of Force Application as a Determinant Factor of Sprint Performance
MORIN, J.-B., EDOUARD, P., & SAMOZINO, P. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318216ea37 · Cited by 542
Mechanical determinants of 100-m sprint running performance
Morin, J.-B., Bourdin, M., Edouard, P., Peyrot, N., Samozino, P., & Lacour, J.-R. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-012-2379-8 · Cited by 503
The biological limits to running speed are imposed from the ground up
Weyand, P. G., Sandell, R. F., Prime, D. N. L., & Bundle, M. W. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00947.2009 · Cited by 326
Self-citation
Metadata
- Authors
- Weyand, P. G., Bundle, M. W., McGowan, C. P., Grabowski, A., Brown, M. B., Kram, R., & Herr, H.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2009-09
- Volume
- 107
- Issue
- 3
- Pages
- 903-911
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2118622667
- Cited by
- 184
- References
- 3
- FWCI
- 6.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.