Determinants of exercise performance in normal men with externally imposed expiratory flow limitation
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
To understand how externally applied expiratory flow limitation (EFL) leads to impaired exercise performance and dyspnea, we studied six healthy males during control incremental exercise to exhaustion (C) and with EFL at ∼1. We measured volume at the mouth (Vm), esophageal, gastric and transdiaphragmatic (Pdi) pressures, maximal exercise power (W˙max) and the difference (Δ) in Borg scale ratings of breathlessness between C and EFL exercise. Optoelectronic plethysmography measured chest wall and lung volume (Vl). From Campbell diagrams, we measured alveolar (Pa) and expiratory muscle (Pmus) pressures, and from Pdi and abdominal motion, an index of diaphragmatic power (W˙di). Four subjects hyperinflated and two did not. EFL limited performance equally to 65%W˙max with Borg = 9–10 in both. At EFLW˙max, inspiratory time (Ti) was 0.66s ± 0.08, expiratory time (Te) 2.12 ± 0.26 s, Pmus ∼40 cmH 2 O and ΔVl-ΔVm = 488.7 ± 74.1 ml. From Pa and Vl, we calculated compressed gas volume (Vc) = 163.0 ± 4.6 ml. The difference, ΔVl-ΔVm-Vc (estimated blood volume shift) was 326 ml ± 66 or 7.2 ml/cmH 2 O Pa. The high Pmus and long Te mimicked a Valsalva maneuver from which the short Ti did not allow recovery. Multiple stepwise linear regression revealed that the difference between C and EFL Pmus accounted for 70.3% of the variance in ΔBorg. ΔW˙di added 12.5%. We conclude that high expiratory pressures cause severe dyspnea and the possibility of adverse circulatory events, both of which would impair exercise performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Respiratory muscle work compromises leg blood flow during maximal exercise
Harms, C. A., Babcock, M. A., McClaran, S. R., Pegelow, D. F., Nickele, G. A., Nelson, W. B., & Dempsey, J. A. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.5.1573 · Cited by 711 · cited 1×
“At maximal exercise in trained normal subjects, respiratory muscles consume about 15% of total body O2 consumption and take a similar percentage of the cardiac output (13, 14).”
BackgroundO'Donnell, D. E., & Webb, K. A. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/148.5.1351 · Cited by 543
O'DONNELL, D. E., LAM, M., & WEBB, K. A. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.5.9804004 · Cited by 532 · cited 3×
“A number of factors may be involved, including shortening of diaphragmatic fiber length, threshold load (9, 21, 22), progressive decrease of inspiratory capacity to a value lower than the desired VT (4, 5, 6, 10, 26 , 28, 38), a decrease in V ˙ E (4, 5), and a decrease in lung compliance, which increases the elastic w…”
BackgroundInfluentialBelman, M. J., Botnick, W. C., & Shin, J. W. (1996) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.153.3.8630581 · Cited by 402 · cited 2×
“One possibility is dynamic hyperinflation (DH), which has often been implicated as a cause of dyspnea and impaired exercise performance in airway obstruction (4, 6, 9, 25, 26, 28, 38).”
BackgroundRespiratory Muscle and Cardiopulmonary Function During Exercise in Very Severe COPD
Montes de Oca, M., Rassulo, J., & Celli, B. R. (1996) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.154.5.8912737 · Cited by 170
Cited by
Flow limitation and dynamic hyperinflation: key concepts in modern respiratory physiology
Calverley, P. M. A., & Koulouris, N. G. (2005) · European Respiratory Journal · doi:10.1183/09031936.04.00113204 · Cited by 258
“This remains true during exercise in healthy subjects, but not if they breathe through a Starling resistor nor is it the case in many COPD patients [ 99 , 101].”
BackgroundExercise starts and ends in the brain
Kayser, B. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0902-7 · Cited by 243
“During expiratory flow-limited exercise the subjects recruit expiratory muscles, develop high expiratory pulmonary pressures impeding venous return, hyperinflate the lungs burdening the inspiratory muscles, and develop a severe sensation of dyspnoea (Kayser et al. 1997; Iandelli et al. 2002; Aliverti et al. 2002).”
BackgroundSelf-citationRegional chest wall volumes during exercise in chronic obstructive pulmonary disease
Aliverti, A. (2004) · Thorax · doi:10.1136/thorax.2003.011494 · Cited by 226
“Patients were considered to show dynamic hyperinflation of the chest wall if the end expiratory Vcw increased above its resting value at maximum workload. Those in whom Vcw was maintained or reduced were described as euvolumic. This terminology was the same as that used in other published papers”
Self-citationChest Wall Kinematics and Breathlessness During Pursed-Lip Breathing in Patients With COPD
Bianchi, R., Gigliotti, F., Romagnoli, I., Lanini, B., Castellani, C., Grazzini, M., & Scano, G. (2004) · Chest · doi:10.1378/chest.125.2.459 · Cited by 144
Self-citationVogiatzis, I. (2005) · Thorax · doi:10.1136/thx.2004.039115 · Cited by 121
Metadata
- Authors
- Iandelli, I., Aliverti, A., Kayser, B., Dellacà, R., Cala, S. J., Duranti, R., Kelly, S., Scano, G., Sliwinski, P., Yan, S., Macklem, P. T., & Pedotti, A.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2002-05-01
- Volume
- 92
- Issue
- 5
- Pages
- 1943-1952
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2003122065
- Cited by
- 113
- References
- 5
- FWCI
- 14.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.