CoChat

Oxygen pressures in the interstitial space and their relationship to those in the blood plasma in resting skeletal muscle

Wilson, David F., Lee, William M. F., Makonnen, Sosina, Finikova, Olga, Apreleva, Sofia, Vinogradov, Sergei A. · 2006 · Journal of Applied Physiology
Cited by 116

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

This study compared oxygen pressures (Po(2)), measured by oxygen-dependent quenching of phosphorescence, in the intravascular (blood plasma) space in the muscle with those in the interstitial (pericellular) space. Our hypothesis was that the capillary wall would not significantly impede oxygen diffusion from the blood plasma to the pericellular space. A new near-infrared oxygen sensitive probe, Oxyphor G3, was used to obtain oxygen distributions in the interstitial space. Oxyphor G3 is a Pd-tetrabenzoporphyrin encapsulated inside generation 2 poly-arylglycine (AG) dendrimer. The periphery of the dendrimer is modified with oligoethylene glycol residues (average molecular weight 350) to make the probe water soluble and biologically inert. Oxyphor G3 was injected into thigh muscle using a 30-gauge needle. Histograms of the Po(2) in the interstitial space were measured in awake and anesthetized animals and compared with those for Oxyphor G2 in the intravascular (blood plasma) space. For awake mice, the lowest 10% of Po(2) values for the interstitial and intravascular spaces (believed to represent capillary bed) were not significantly different [23.8 (SD 4.5) and 25 Torr (SD 4.3), respectively], whereas, in isoflurane-anesthetized mice, there was a small but significant (P = 0.01) difference [20.4 (SD 6.3) and 27.9 Torr (SD 3.5), respectively]. The peak values for the histograms for the interstitial space in awake and isoflurane-anesthetized mice were 40.8 (SD 7.5) and 36.9 Torr (SD 8.3), respectively, whereas those for the intravascular space were 52.2 (SD 4.9) and 55.9 Torr (SD 8.4), respectively, showing no significant difference due to isoflurane anesthesia. The histograms for the intravascular space were significantly wider, with more contribution at higher Po(2) values. A different anesthetic, ketamine plus xylazine injected intraperitoneally, caused a marked decrease in the tissue Po(2) values in both spaces, with the time course and extent of the decrease dependent on the time after injection and variable among mice. It was, therefore, not further used.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00394.2006

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Wilson, D. F., Lee, W. M. F., Makonnen, S., Finikova, O., Apreleva, S., & Vinogradov, S. A.
Venue
Journal of Applied Physiology
Published
2006-12
Volume
101
Issue
6
Pages
1648-1656
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2117876339
Cited by
116
References
1
FWCI
7.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.