The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Oxygen‐Sensing Methods in Biomedicine from the Macroscale to the Microscale
Abstract
Oxygen monitoring has been a topic of exhaustive study given its central role in the biochemistry of life. The ability to quantify the physiological distribution and real‐time dynamics of oxygen from sub‐cellular to macroscopic levels is required to fully understand the mechanisms associated with both normal physiology and disease states. This Review will present the most significant recent advances in the development of oxygen‐sensing materials and techniques, including polarographic, nuclear medicine, magnetic resonance, and optical approaches, that can be applied specifically for the real‐time monitoring of oxygen dynamics in cellular and tissue environments. As some of the most exciting recent advances in synthetic methods and biomedical applications have been in the field of optical oxygen sensors, a major focus will be on the development of these toolkits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Targeting hypoxia in cancer therapy
Wilson, W. R., & Hay, M. P. (2011) · Nature Reviews Cancer · doi:10.1038/nrc3064 · Cited by 3,172
Why is the partial oxygen pressure of human tissues a crucial parameter? Small molecules and hypoxia
Carreau, A., Hafny‐Rahbi, B. E., Matejuk, A., Grillon, C., & Kieda, C. (2011) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2011.01258.x · Cited by 1,246
Folkman, J. (2006) · Annual Review of Medicine · doi:10.1146/annurev.med.57.121304.131306 · Cited by 1,209
Direct measurement of local oxygen concentration in the bone marrow of live animals
Spencer, J. A., Ferraro, F., Roussakis, E., Klein, A., Wu, J., Runnels, J. M., Zaher, W., Mortensen, L. J., Alt, C., Turcotte, R., et al. (2014) · Nature · doi:10.1038/nature13034 · Cited by 1,167
Self-citationKrohn, K. A., Link, J. M., & Mason, R. P. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045914 · Cited by 506
He, G., Shankar, R. A., Chzhan, M., Samouilov, A., Kuppusamy, P., & Zweier, J. L. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.8.4586 · Cited by 383
Liu, K. J., Gast, P., Moussavi, M., Norby, S. W., Vahidi, N., Walczak, T., Wu, M., & Swartz, H. M. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.12.5438 · Cited by 318
Mahnke, A., Meier, R. J., Schatz, V., Hofmann, J., Castiglione, K., Schleicher, U., Wolfbeis, O. S., Bogdan, C., & Jantsch, J. (2014) · Journal of Investigative Dermatology · doi:10.1038/jid.2014.121 · Cited by 69
Cited by
Fiber-Optic Chemical Sensors and Biosensors (2015–2019)
Wang, X.-D., & Wolfbeis, O. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04708 · Cited by 833
Long‐Lived Room‐Temperature Phosphorescence for Visual and Quantitative Detection of Oxygen
Zhou, Y., Qin, W., Du, C., Gao, H., Zhu, F., & Liang, G. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201906312 · Cited by 301
Metadata
- Authors
- Roussakis, E., Li, Z., Nichols, A. J., & Evans, C. L.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2015-06-17
- Volume
- 54
- Issue
- 29
- Pages
- 8340-8362
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2133154940
- Cited by
- 184
- References
- 10
- FWCI
- 13.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oxygen‐Sensing Methods in Biomedicine from the Macroscale to the Microscale. https://app.cochat.ai/papers/10.1002/anie.201410646
- The paper
- Roussakis, E., Li, Z., Nichols, A. J., & Evans, C. L. (2015). Oxygen‐Sensing Methods in Biomedicine from the Macroscale to the Microscale. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.201410646
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.