CoChat

Principles, insights, and potential pitfalls of the noninvasive determination of muscle oxidative capacity by near-infrared spectroscopy

Open access
Adami, Alessandra, Rossiter, Harry B. · 2018 · Journal of Applied Physiology
Cited by 70

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Skeletal muscle oxidative capacity is highly plastic, strongly associated with whole-body aerobic capacity (16, 18) and state of health. Loss of muscle oxidative capacity is associated with physical inactivity, aging and chronic disease (17), and has been implicated in the pathophysiology of obesity and diabetes (21). Evaluating these changes has traditionally been limited to invasive or costly assessments (biopsy or ³¹P MRS). To address this, Hamaoka and colleagues developed an innovative, non-invasive approach using near-infrared spectroscopy (NIRS) to quantitatively measure muscle oxygen consumption (mV̇O₂; 12) and use this to infer muscle oxidative capacity based on the mV̇O₂ recovery rate constant (k) (23; later modified 26). This technique has been subsequently used to interpret relative differences in oxidative capacity across a wide range of muscles, ages and disease states (Figure 1C). The purpose of this Viewpoint is to open a discussion on the principles, insights and potential pitfalls of using NIRS to measure k and infer muscle oxidative capacity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00445.2017

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 70

Metadata

Authors
Adami, A., & Rossiter, H. B.
Venue
Journal of Applied Physiology
Published
2018-01-01
Volume
124
Issue
1
Pages
245-248
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2724512295
Cited by
70
References
11
FWCI
5.78
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Principles, insights, and potential pitfalls of the noninvasive determination of muscle oxidative capacity by near-infrared spectroscopy. https://app.cochat.ai/papers/10.1152/japplphysiol.00445.2017
The paper
Adami, A., & Rossiter, H. B. (2018). Principles, insights, and potential pitfalls of the noninvasive determination of muscle oxidative capacity by near-infrared spectroscopy. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00445.2017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.