Skeletal muscle V̇o2kinetics by the NIRS repeated occlusions method during the recovery from cycle ergometer exercise
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Near-infrared spectroscopy (NIRS) has been utilized as a noninvasive method to evaluate skeletal muscle mitochondrial function in humans, by calculating muscle V̇o 2(V̇o 2 m) recovery (off-) kinetics following short light-intensity plantar flexion exercise. The aim of the present study was to determine V̇o 2 m off- kinetics following standard cycle ergometer exercise of different intensities. Fifteen young physically active healthy men performed an incremental exercise (INCR) up to exhaustion and two repetitions of constant work-rate (CWR) exercises at 80% of gas exchange threshold (GET; MODERATE) and at 40% of the difference between GET and peak pulmonary V̇o 2(V̇o 2 p; HEAVY). V̇o 2 p and vastus lateralis muscle fractional O 2 extraction by NIRS (Δ[deoxy(Hb+Mb)]) were recorded continuously. Transient arterial occlusions were carried out at rest and during the recovery for V̇o 2 m calculation. All subjects tolerated the repeated occlusions protocol without problems. The quality of the monoexponential fitting for V̇o 2 m off-kinetics analysis was excellent (0.93≤ r 2≤0.99). According to interclass correlation coefficient, the test-retest reliability was moderate to good. V̇o 2 m values at the onset of recovery were ~27, ~38, and ~35 times higher (in MODERATE, HEAVY, and INCR, respectively) than at rest. The time constants (τ) of V̇o 2 m off-kinetics were lower ( P < 0.001) following MODERATE (29.1 ± 6.8 s) vs. HEAVY (40.8 ± 10.9) or INCR (42.9 ± 10.9), suggesting an exercise intensity dependency of V̇o 2 m off-kinetics. Only following MODERATE the V̇o 2 m off-kinetics were faster than the V̇o 2 p off-kinetics. V̇o 2 m off-kinetics, determined noninvasively by the NIRS repeated occlusions technique, can be utilized as a functional evaluation tool of skeletal muscle oxidative metabolism also following conventional cycle ergometer exercise. NEW & NOTEWORTHY This is the first study in which muscle V̇o 2 recovery kinetics, determined noninvasively by near-infrared spectroscopy (NIRS) by utilizing the repeated occlusions method, was applied following standard cycle ergometer exercise of different intensities. The results demonstrate that muscle V̇o 2 recovery kinetics, determined noninvasively by the NIRS repeated occlusions technique, can be utilized as a functional evaluation tool of skeletal muscle oxidative metabolism also following conventional cycle ergometer exercise, overcoming significant limitations associated with the traditionally proposed protocol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Age-predicted maximal heart rate revisited
Tanaka, H., Monahan, K. D., & Seals, D. R. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01054-8 · Cited by 3,775
Maximal perfusion of skeletal muscle in man.
Andersen, P., & Saltin, B. (1985) · The Journal of Physiology · doi:10.1113/jphysiol.1985.sp015794 · Cited by 1,250
Muscle O2 uptake kinetics in humans: implications for metabolic control
Grassi, B., Poole, D. C., Richardson, R. S., Knight, D. R., Erickson, B. K., & Wagner, P. D. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.3.988 · Cited by 561
Self-citationUnderstanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Slow Component of V˙O2 Kinetics: Mechanistic Bases and Practical Applications
JONES, A. M., GRASSI, B., CHRISTENSEN, P. M., KRUSTRUP, P., BANGSBO, J., & POOLE, D. C. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31821fcfc1 · Cited by 353
Self-citationGrassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
Self-citationHamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Effect of Inorganic Nitrate on Exercise Capacity in Heart Failure With Preserved Ejection Fraction
Zamani, P., Rawat, D., Shiva-Kumar, P., Geraci, S., Bhuva, R., Konda, P., Doulias, P.-T., Ischiropoulos, H., Townsend, R. R., Margulies, K. B., et al. (2015) · Circulation · doi:10.1161/circulationaha.114.012957 · Cited by 307
Effects of hypoxic hypoxia on O2uptake and heart rate kinetics during heavy exercise
Engelen, M., Porszasz, J., Riley, M., Wasserman, K., Maehara, K., & Barstow, T. J. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.6.2500 · Cited by 207
Ryan, T. E., Southern, W. M., Reynolds, M. A., & McCully, K. K. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00835.2013 · Cited by 192
Wüst, R. C. I., van der Laarse, W. J., & Rossiter, H. B. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2012.241992 · Cited by 44
Cited by
Koutlas, A., Smilios, I., Kokkinou, E. M., Myrkos, A., Kounoupis, A., Dipla, K., & Zafeiridis, A. (2024) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2022.2159309 · Cited by 18
“…the technique used in this study, is independent of the participant’s motivation, it does not require exercise modalities and complex measuring and analyzing procedures compared to previous NIRS approaches (Beever et al., 2020; Lagerwaard et al., 2020; Sumner et al., 2020; Zuccarelli et al., 2020).”
MethodArnold, J. I., Yogev, A., Nelson, H., van Hooff, M., & Koehle, M. S. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1449384 · Cited by 8
Venckunas, T., Satas, A., Brazaitis, M., Eimantas, N., Sipaviciene, S., & Kamandulis, S. (2024) · Sensors · doi:10.3390/s24072277 · Cited by 6
“The oxygen consumption rate in each participant for a total of 22 measurements increased by no less than three times, a recommended minimum for the successful application of NIRS in estimating muscle mitochondrial capacity [10,20,26].”
BackgroundMethodInfluential
Metadata
- Authors
- Zuccarelli, L., do Nascimento Salvador, P. C., Del Torto, A., Fiorentino, R., & Grassi, B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2020-03-01
- Volume
- 128
- Issue
- 3
- Pages
- 534-544
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W3001119936
- Cited by
- 32
- References
- 11
- FWCI
- 3.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.