Apparent latent heat of evaporation from clothing: attenuation and “heat pipe” effects
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Investigating claims that a clothed person's mass loss does not always represent their evaporative heat loss (EVAP), a thermal manikin study was performed measuring heat balance components in more detail than human studies would permit. Using clothing with different levels of vapor permeability and measuring heat losses from skin controlled at 34°C in ambient temperatures of 10, 20, and 34°C with constant vapor pressure (1 kPa), additional heat losses from wet skin compared with dry skin were analyzed. EVAP based on mass loss ( E mass) measurement and direct measurement of the extra heat loss by the manikin due to wet skin ( E app) were compared. A clear discrepancy was observed. E mass overestimated E app in warm environments, and both under and overestimations were observed in cool environments, depending on the clothing vapor permeability. At 34°C, apparent latent heat (λ app) of pure evaporative cooling was lower than the physical value (λ; 2,430 J/g) and reduced with increasing vapor resistance up to 45%. At lower temperatures, λ app increases due to additional skin heat loss via evaporation of moisture that condenses inside the clothing, analogous to a heat pipe. For impermeable clothing, λ app even exceeds λ by four times that value at 10°C. These findings demonstrate that the traditional way of calculating evaporative heat loss of a clothed person can lead to substantial errors, especially for clothing with low permeability, which can be positive or negative, depending on the climate and clothing type. The model presented explains human subject data on EVAP that previously seemed contradictive.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International Organization for Standardization
(2011) · SpringerReference · doi:10.1007/springerreference_16847 · Cited by 12,534
Holman, J. P. (1976) · Cited by 9,157
American society for testing and materials
Mather, B., & Etris, S. F. (2006) · Encyclopedia of Earth Science · doi:10.1007/0-387-30720-6_5 · Cited by 5,558
Physiology of Heat Regulation and the Science of Clothing
(1950) · Journal of the American Medical Association · doi:10.1001/jama.1950.02910340073037 · Cited by 233
Heat of evaporation of sweat: thermodynamic considerations.
Wenger, C. B. (1972) · Journal of Applied Physiology · doi:10.1152/jappl.1972.32.4.456 · Cited by 148 · cited 3×
“This total amount of heat taken by evaporation was found to be constant for a certain temperature (15, 39), but the present study clearly shows that the source for this heat of evaporation is not only the body but must also be the environment within the clothing.”
BackgroundClothing Thermal Insulation During Sweating
Chen, Y. S., Fan, J., & Zhang, W. (2003) · Textile Research Journal · doi:10.1177/004051750307300210 · Cited by 148 · cited 3×
“Also for many manikins, measurement of vapor resistance is based on mass loss (2, 6).”
BackgroundInfluentialHAVENITH, G., HEUS, R., & LOTENS, W. A. (1990) · Ergonomics · doi:10.1080/00140139008925308 · Cited by 143 · cited 1×
“The latter is often done in clothing research and thermal tolerance studies (17, 19, 20, 31), where the DRY value is used to calculate the thermal insulation of the clothing, and EVAP is used to calculate the clothing vapor resistance.”
MethodSelf-citationClothing evaporative heat resistance—proposal for improved representation in standards and models
Havenith, G., Holmér, I., den Hartog, E. A., & Parsons, K. C. (1999) · The Annals of Occupational Hygiene · doi:10.1016/s0003-4878(99)00052-6 · Cited by 130
Self-citationWater Vapor Transfer and Condensation Effects in Multilayer Textile Combinations
Rossi, R. M., Gross, R., & May, H. (2004) · Textile Research Journal · doi:10.1177/004051750407400101 · Cited by 74 · cited 1×
“(37) observed that, for clothing incorporating a laminate, vapor resistance based on measurements of weight loss increases with reducing temperature.”
BackgroundEffects of condensation in clothing on heat transfer
Lotens, W. A., LINDE, F. J. G. V. D., & Havenith, G. (1995) · Ergonomics · doi:10.1080/00140139508925177 · Cited by 66 · cited 5×
“The added heat loss when the skin is wet is then attributed to evaporation out of the clothing to the environment (E), extra conduction in the fabrics due to moisture (C), and evaporation of moisture at the skin that recondenses in and releases heat to the outer clothing layers (D) without evaporating to the environme…”
BackgroundInfluentialSelf-citationEffects of moisture absorption in clothing on the human heat balance
Lotens, W. A., & Havenith, G. (1995) · Ergonomics · doi:10.1080/00140139508925176 · Cited by 62 · cited 1×
“The moisture may be sorbed and subsequently desorbed by textile fibers, it may condense in outer layers if these are colder than the skin, it may be ventilated from the clothing microclimate, or finally it may diffuse through the outer clothing layer (3, 10, 11, 12, 13, 30, 34).”
BackgroundSelf-citationNon-evaporative effects of a wet mid layer on heat transfer through protective clothing
Bröde, P., Havenith, G., Wang, X., Candas, V., DenHartog, E., Griefahn, B., Holmér, I., Kuklane, K., Meinander, H., Nocker, W., et al. (2007) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0629-y · Cited by 53
Self-citationCoupled Heat and Mass Transfer Through Hygroscopic Porous Materials-Application to Clothing Layers.
Gibson, P., & Charmchi, M. (1997) · Sen i Gakkaishi · doi:10.2115/fiber.53.5_183 · Cited by 35 · cited 10×
“Assuming an evaporative cooling efficiency of unity ( 2,430 J/g) will introduce an error in their results, as demonstrated in the present experiment.”
BackgroundMethodInfluentialSnellen, J. W., Mitchell, D., & Wyndham, C. H. (1970) · Journal of Applied Physiology · doi:10.1152/jappl.1970.29.1.40 · Cited by 32 · cited 2×
“Values for for evaporation of human sweat have been debated in the literature, considering the effects of temperature, humidity, and sweat osmolality, but suggested values ranging from 2,696 J/g (16) to 2,595 (32, 38) and 2,398 J/g (33) have finally converged to the latent heat of evaporation of pure water (39), only…”
BackgroundDirect measurement of the thermal responses of nude resting men in dry environments
Mitchell, D., Wyndham, C. H., Atkins, A. R., Vermeulen, A. J., Hofmeyr, H., Strydom, N. B., & Hodgson, T. (1968) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00596389 · Cited by 26
Havenith, G. (2002) · Textile Research Journal · doi:10.1177/004051750207200401 · Cited by 19 · cited 2×
“The latter is often done in clothing research and thermal tolerance studies (17, 19, 20, 31), where the DRY value is used to calculate the thermal insulation of the clothing, and EVAP is used to calculate the clothing vapor resistance.”
BackgroundMethodSelf-citationAssessment of thermal properties of of protective clothing and their use
Havenith, G., Holmér, I., Meinander, H., DenHartog, E., Richards, M., Bröde, P., & Candas (2006) · Lund University Publications (Lund University) · Cited by 17
Self-citationReproducibility of body temperature response to standardized test conditions when assessing clothing
Jetté, M., Quenneville, J., Thoden, J., & Livingstone, S. (1995) · Ergonomics · doi:10.1080/00140139508925172 · Cited by 11
Cited by
Deriving the operational procedure for the Universal Thermal Climate Index (UTCI)
Bröde, P., Fiala, D., Błażejczyk, K., Holmér, I., Jendritzky, G., Kampmann, B., Tinz, B., & Havenith, G. (2012) · International Journal of Biometeorology · doi:10.1007/s00484-011-0454-1 · Cited by 1,243
Self-citationBody mapping of sweating patterns in male athletes in mild exercise-induced hyperthermia
Smith, C. J., & Havenith, G. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1744-8 · Cited by 375
“Those that have investigated regional sweating observed considerable variation between the sites tested (Cotter et al. 1995; Fogarty et al. 2007; Havenith et al. 2008a; Hertzman 1957; Kuno 1956; Machado-Moreira et al. 2008a, b, c; Ogata 1935; Smith et al. 2007; Taylor et al. 2006; Weiner 1945).”
BackgroundMethodResultInfluentialSelf-citationBR^|^Ouml;DE, P., BLAZEJCZYK, K., FIALA, D., HAVENITH, G., HOLM^|^Eacute;R, I., JENDRITZKY, G., KUKLANE, K., & KAMPMANN, B. (2013) · Industrial Health · doi:10.2486/indhealth.2012-0098 · Cited by 171
Self-citationWang, F., Kuklane, K., Gao, C., & Holmér, I. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/2/007 · Cited by 83
Self-citationOn the Effect of Thermophysical Properties of Clothing on the Heat Strain Predicted by PHS Model
d’Ambrosio Alfano, F. R., Palella, B. I., Riccio, G., & Malchaire, J. (2016) · Annals of Occupational Hygiene · doi:10.1093/annhyg/mev070 · Cited by 60
Metadata
- Authors
- Havenith, G., Richards, M. G., Wang, X., Bröde, P., Candas, V., den Hartog, E., Holmér, I., Kuklane, K., Meinander, H., & Nocker, W.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2008-01
- Volume
- 104
- Issue
- 1
- Pages
- 142-149
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2150993852
- Cited by
- 159
- References
- 18
- FWCI
- 5.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.