Segment-specific resistivity improves body fluid volume estimates from bioimpedance spectroscopy in hemodialysis patients
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Discrepancies in body fluid estimates between segmental bioimpedance spectroscopy (SBIS) and gold-standard methods may be due to the use of a uniform value of tissue resistivity to compute extracellular fluid volume (ECV) and intracellular fluid volume (ICV). Discrepancies may also arise from the exclusion of fluid volumes of hands, feet, neck, and head from measurements due to electrode positions. The aim of this study was to define the specific resistivity of various body segments and to use those values for computation of ECV and ICV along with a correction for unmeasured fluid volumes. Twenty-nine maintenance hemodialysis patients (16 men) underwent body composition analysis including whole body MRI, whole body potassium (40 K) content, deuterium, and sodium bromide dilution, and segmental and wrist-to-ankle bioimpedance spectroscopy, all performed on the same day before a hemodialysis. Segment-specific resistivity was determined from segmental fat-free mass (FFM; by MRI), hydration status of FFM (by deuterium and sodium bromide), tissue resistance (by SBIS), and segment length. Segmental FFM was higher and extracellular hydration of FFM was lower in men compared with women. Segment-specific resistivity values for arm, trunk, and leg all differed from the uniform resistivity used in traditional SBIS algorithms. Estimates for whole body ECV, ICV, and total body water from SBIS using segmental instead of uniform resistivity values and after adjustment for unmeasured fluid volumes of the body did not differ significantly from gold-standard measures. The uniform tissue resistivity values used in traditional SBIS algorithms result in underestimation of ECV, ICV, and total body water. Use of segmental resistivity values combined with adjustment for body volumes that are neglected by traditional SBIS technique significantly improves estimations of body fluid volume in hemodialysis patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152
Organ-tissue mass measurement allows modeling of REE and metabolically active tissue mass
Gallagher, D., Belmonte, D., Deurenberg, P., Wang, Z., Krasnow, N., Pi-Sunyer, F. X., & Heymsfield, S. B. (1998) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1998.275.2.e249 · Cited by 470
Self-citationWhole-body impedance–what does it measure?
Foster, K., & Lukaski, H. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.388s · Cited by 429
Measures of body composition in blacks and whites: a comparative review
Wagner, D. R., & Heyward, V. H. (2000) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/71.6.1392 · Cited by 397
Nutritional assessment with bioelectrical impedance analysis in maintenance hemodialysis patients.
Chertow, G. M., Lowrie, E. G., Wilmore, D. W., Gonzalez, J., Lew, N. L., Ling, J., Leboff, M. S., Gottlieb, M. N., Huang, W., & Zebrowski, B. (1995) · Journal of the American Society of Nephrology · doi:10.1681/asn.v6175 · Cited by 257
Cited by
Bioimpedance at the Bedside: Current Applications, Limitations, and Opportunities
Mulasi, U., Kuchnia, A. J., Cole, A. J., & Earthman, C. P. (2015) · Nutrition in Clinical Practice · doi:10.1177/0884533614568155 · Cited by 337
Davies, S. J., & Davenport, A. (2014) · Kidney International · doi:10.1038/ki.2014.207 · Cited by 314
Hsu, J., Johansen, K. L., Hsu, C.-Y., Kaysen, G. A., & Chertow, G. M. (2008) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.00090108 · Cited by 81
Self-citationAssessment of body cell mass at bedside in critically ill patients
Savalle, M., Gillaizeau, F., Maruani, G., Puymirat, E., Bellenfant, F., Houillier, P., Fagon, J.-Y., & Faisy, C. (2012) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00502.2011 · Cited by 60
“Using a measuring tape, height was determined with the patient lying in a supine position, as were right arm (A), trunk (T), and right leg (L) lengths and the mean circumferences of each, as described previously (48).”
Method
Metadata
- Authors
- Zhu, F., Kuhlmann, M. K., Kaysen, G. A., Sarkar, S., Kaitwatcharachai, C., Khilnani, R., Stevens, L., Leonard, E. F., Wang, J., Heymsfield, S., & Levin, N. W.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2006-02
- Volume
- 100
- Issue
- 2
- Pages
- 717-724
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1996011595
- Cited by
- 79
- References
- 5
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.