QDR 4500A DXA overestimates fat-free mass compared with criterion methods
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This study evaluated the accuracy with which the dual-energy X-ray absorptiometer (Hologic QDR 4500A) measured fat-free mass (FFM), fat mass (FM), and hydration of FFM. In a study of 58 men and women (ages 70–79 yr), the QDR 4500A was found to provide a systematically higher estimate of FFM and lower estimate of FM than a four-component model of body composition. A correction factor from this study was developed and applied to two other samples ( n = 13 and 37). We found mean corrected levels of FFM and FM to be equivalent to that obtained by the four-component model or total body water. In addition, the hydration of the corrected FFM was closer to the established hydration level in adult samples and that obtained from the four-component model. These findings suggest that the current calibration of the fan-beam system of the Hologic QDR 4500A provides an overestimate of FFM and underestimate of FM compared with reference methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
LOHMAN, T. G., HARRIS, M., TEIXEIRA, P. J., & WEISS, L. (2000) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2000.tb06420.x · Cited by 153
Self-citationEllis, K. J., & Shypailo, R. J. (1998) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1998.13.10.1613 · Cited by 108
Cited by
Newman, A. B., Lee, J. S., Visser, M., Goodpaster, B. H., Kritchevsky, S. B., Tylavsky, F. A., Nevitt, M., & Harris, T. B. (2005) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/82.4.872 · Cited by 445
Self-citationSchoeller, D. A., Tylavsky, F. A., Baer, D. J., Chumlea, W. C., Earthman, C. P., Fuerst, T., Harris, T. B., Heymsfield, S. B., Horlick, M., Lohman, T. G., et al. (2005) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/81.5.1018 · Cited by 253
Self-citationShafer, K. J., Siders, W. A., Johnson, L. K., & Lukaski, H. C. (2009) · Nutrition · doi:10.1016/j.nut.2008.07.004 · Cited by 223
Lee, J. S., Visser, M., Tylavsky, F. A., Kritchevsky, S. B., Schwartz, A. V., Sahyoun, N., Harris, T. B., Newman, A. B., & Study, F. T. H. A. (2010) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glp042 · Cited by 108
Self-citationLazzer, S., Bedogni, G., Agosti, F., De Col, A., Mornati, D., & Sartorio, A. (2008) · British Journal of Nutrition · doi:10.1017/s0007114508922558 · Cited by 106
“DXA has been validated against the four-compartment model((5,6)), underwater weighing((7)) and direct chemical analysis((4,8)).”
Method
Metadata
- Authors
- Tylavsky, F., Lohman, T., Blunt, B. A., Schoeller, D. A., Fuerst, T., Cauley, J. A., Nevitt, M. C., Visser, M., & Harris, T. B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2003-03-01
- Volume
- 94
- Issue
- 3
- Pages
- 959-965
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2163872864
- Cited by
- 68
- References
- 3
- FWCI
- 3.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.