CoChat

Is the ratio of flow-mediated dilation and shear rate a statistically sound approach to normalization in cross-sectional studies on endothelial function?

Atkinson, Greg, Batterham, Alan M., Black, Mark A., Cable, Nigel T., Hopkins, Nicola D., Dawson, Ellen A., Thijssen, Dick H. J., Jones, Helen, Tinken, Toni M., Green, Daniel J. · 2009 · Journal of Applied Physiology
Cited by 107

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

It has been deemed important to normalize flow-mediated dilation (FMD), a marker of endothelial function, for between-subject differences in the eliciting shear rate (SR) stimulus. Conventionally, FMD is divided by the area under the curve of the SR stimulus. In the context of a cross-sectional comparison across different age cohorts, we examined whether this ratio approach adhered to established statistical assumptions necessary for reliable normalization. To quantify brachial artery FMD and area under the curve of SR, forearm cuff inflation to suprasystolic pressure was administered for 5 min to 16 boys aged 10.9 yr (SD 0.3), 48 young men aged 25.3 yr (SD 4.2), and 15 older men aged 57.5 yr (SD 4.3). Mean differences between age groups were statistically significant ( P < 0.001) for nonnormalized FMD [children: 10.4% (SD 5.4), young adults: 7.5% (SD 2.9), older adults: 5.6% (SD 2.0)] but not for ratio-normalized FMD ( P = 0.10). Moreover, all assumptions necessary for reliable use of ratio-normalization were violated, including regression slopes between SR and FMD that had y-intercepts greater than zero ( P < 0.05), nonlinear and unstable relations between the normalized ratios and SR, skewed data distributions, and heteroscedastic variance. Logarithmic transformation of SR and FMD before ratio calculation improved adherence to these assumptions and resulted in age differences similar to the nonnormalized data ( P = 0.03). In conclusion, although ratio normalization of FMD altered findings about age differences in endothelial function, this could be explained by violation of statistical assumptions. We recommend that exploration of these assumptions should be routine in future research. If the relationship between SR and FMD is generally found to be weak or nonlinear or variable between samples, then ratio normalization should not be applied.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00779.2009

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 107

Metadata

Authors
Atkinson, G., Batterham, A. M., Black, M. A., Cable, N. T., Hopkins, N. D., Dawson, E. A., Thijssen, D. H. J., Jones, H., Tinken, T. M., & Green, D. J.
Venue
Journal of Applied Physiology
Published
2009-12
Volume
107
Issue
6
Pages
1893-1899
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2140244782
Cited by
107
References
7
FWCI
6.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Is the ratio of flow-mediated dilation and shear rate a statistically sound approach to normalization in cross-sectional studies on endothelial function? https://app.cochat.ai/papers/10.1152/japplphysiol.00779.2009
The paper
Atkinson, G., Batterham, A. M., Black, M. A., Cable, N. T., Hopkins, N. D., Dawson, E. A., Thijssen, D. H. J., Jones, H., Tinken, T. M., & Green, D. J. (2009). Is the ratio of flow-mediated dilation and shear rate a statistically sound approach to normalization in cross-sectional studies on endothelial function? Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00779.2009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.