CoChat

Muscle strength response to strength training is influenced by insulin-like growth factor 1 genotype in older adults

Kostek, Matthew C., Delmonico, Matthew J., Reichel, Jonathan B., Roth, Stephen M., Douglass, Larry, Ferrell, Robert E., Hurley, Ben F. · 2005 · Journal of Applied Physiology
Cited by 113

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Strength training (ST) is considered an intervention of choice for the prevention and treatment of sarcopenia. Reports in the literature have suggested that the insulin-like growth factor I protein (IGF-I) plays a major role in ST-induced skeletal muscle hypertrophy and strength improvements. A microsatellite repeat in the promoter region of the IGF1 gene has been associated with IGF-I blood levels and phenotypes related to IGF-I in adult men and women. To examine the influence of this polymorphism on muscle hypertrophic and strength responses to ST, we studied 67 Caucasian men and women before and after a 10-wk single-leg knee-extension ST program. One repetition maximum strength, muscle volume via computed tomography, and muscle quality were assessed at baseline and after 10 wk of training. The IGF1 repeat promoter polymorphism and three single-nucleotide polymorphisms were genotyped. For the promoter polymorphism, subjects were grouped as homozygous for the 192 allele, heterozygous, or noncarriers of the 192 allele. After 10 wk of training, 1-repetition maximum, muscle volume, and muscle quality increased significantly for all groups combined ( P < 0.001). However, carriers of the 192 allele gained significantly more strength with ST than noncarriers of the 192 allele ( P = 0.02). There was also a nonsignificant trend for a greater increase in muscle volume in 192 carriers than noncarriers ( P = 0.08). No significant associations were observed for the other polymorphisms studied. Thus these data suggest that the IGF1 promoter polymorphism may influence the strength response to ST. Larger sample sizes should be used in future studies to verify these results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00817.2004

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 113

Metadata

Authors
Kostek, M. C., Delmonico, M. J., Reichel, J. B., Roth, S. M., Douglass, L., Ferrell, R. E., & Hurley, B. F.
Venue
Journal of Applied Physiology
Published
2005-06
Volume
98
Issue
6
Pages
2147-2154
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2015263591
Cited by
113
References
6
FWCI
3.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Muscle strength response to strength training is influenced by insulin-like growth factor 1 genotype in older adults. https://app.cochat.ai/papers/10.1152/japplphysiol.00817.2004
The paper
Kostek, M. C., Delmonico, M. J., Reichel, J. B., Roth, S. M., Douglass, L., Ferrell, R. E., & Hurley, B. F. (2005). Muscle strength response to strength training is influenced by insulin-like growth factor 1 genotype in older adults. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00817.2004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.