Noninvasive determination of exercise-induced hydrodgen ion threshold through direct optical measurement
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The intensity of exercise above which oxygen uptake (V̇o 2) does not account for all of the required energy to perform work has been associated with lactate accumulation in the blood (lactate threshold, LT) and elevated carbon dioxide output (gas exchange threshold). An increase in hydrogen ion concentration ([H+]) is approximately concurrent with elevation of blood lactate and CO 2 output during exercise. Near-infrared spectra (NIRS) and invasive interstitial fluid pH (pHm) were measured in the flexor digitorum profundus during handgrip exercise to produce a mathematical model relating the two measures with an estimated error of 0.035 pH units. This NIRS pHm model was subsequently applied to spectra collected from the vastus lateralis of 10 subjects performing an incremental-intensity cycle protocol. Muscle oxygen saturation (SmO 2) was also calculated from spectra. We hypothesized that a H+ threshold could be identified for these subjects and that it would be different from but correlated with the LT. Lactate, gas exchange, SmO 2, and H+ thresholds were determined as a function of V̇o 2 using bilinear regression. LT was significantly different from both the gas exchange threshold (Δ = 0.27 ± 0.29 l/min) and H+ threshold (Δ = 0.29 ± 0.23 l/min), but the gas exchange threshold was not significantly different from the H+ threshold (Δ = 0.00 ± 0.38 l/min). The H+ threshold was strongly correlated with LT ( R 2 = 0.95) and the gas exchange threshold ( R 2 = 0.85). This initial study demonstrates the feasibility of noninvasive pHm estimations, the determination of H+ threshold, and the relationship between H+ and classical metabolic thresholds during incremental exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669 · cited 1×
“Near-infrared spectroscopy (NIRS) is most commonly used to measure capillary oxygen saturation in muscle (SmO2) (20); however, we have shown that in the setting of local hypovolemia and ischemia, NIRS also can be used to noninvasively and continuously measure muscle, or interstitial fluid, pH (pHm) (26, 43).”
MethodMuscle O2 uptake kinetics in humans: implications for metabolic control
Grassi, B., Poole, D. C., Richardson, R. S., Knight, D. R., Erickson, B. K., & Wagner, P. D. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.3.988 · Cited by 561
Blood lactate accumulation and muscle deoxygenation during incremental exercise
Grassi, B., Quaresima, V., Marconi, C., Ferrari, M., & Cerretelli, P. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.1.348 · Cited by 248 · cited 1×
“NIRS has previously been used to estimate LT or VT during incremental cycling by analyzing trends in the deoxyhemoglobin concentration (HHb) (12, 16), multiple calculated parameters (34), and raw absorbance spectra (4).”
MethodDetection of ventilatory threshold using near infrared spectroscopy in men and women
BHAMBHANI, Y. N., BUCKLEY, S. M., & SUSAKI, T. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199703000-00017 · Cited by 89 · cited 2×
“x y0 s1(x x0), x x0 y0 s2(x x0), x x0 (4)”
MethodWhich common NIRS variable reflects muscle estimated lactate threshold most closely?
Wang, L., Yoshikawa, T., Hara, T., Nakao, H., Suzuki, T., & Fujimoto, S. (2006) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h06-069 · Cited by 54 · cited 2×
“(34) used the same method employed in this study to identify LT and found that change from baseline HHb was the best predictor of LT and VT compared with change from baseline oxygenated hemoglobin (O2Hb), total hemoglobin index, and the tissue oxygenation index.”
Method
Cited by
Ferrari, M., Muthalib, M., & Quaresima, V. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0230 · Cited by 450
Grassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
“Soller et al.(122) developed a mathematical model, which correlated NIRS spectra with muscle pH (pHm) values obtained invasively by sensors placed in the muscle.”
BackgroundMethodInfluentialFarzam, P., Starkweather, Z., & Franceschini, M. A. (2018) · Physiological Reports · doi:10.14814/phy2.13664 · Cited by 107
Boone, J., Barstow, T. J., Celie, B., Prieur, F., & Bourgois, J. (2016) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2015-0261 · Cited by 70
Determination of Maximal Lactate Steady State in Healthy Adults: Can NIRS Help?
BELLOTTI, C., CALABRIA, E., CAPELLI, C., & POGLIAGHI, S. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182828ab2 · Cited by 65
Metadata
- Authors
- Soller, B. R., Yang, Y., Lee, S. M. C., Wilson, C., & Hagan, R. D.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2008-03
- Volume
- 104
- Issue
- 3
- Pages
- 837-844
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2037169389
- Cited by
- 29
- References
- 5
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.