CoChat

Noninvasive determination of exercise-induced hydrodgen ion threshold through direct optical measurement

Soller, Babs R., Yang, Ye, Lee, Stuart M. C., Wilson, Cassie, Hagan, R. Donald · 2008 · Journal of Applied Physiology
Cited by 29

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

The intensity of exercise above which oxygen uptake (V̇o 2) does not account for all of the required energy to perform work has been associated with lactate accumulation in the blood (lactate threshold, LT) and elevated carbon dioxide output (gas exchange threshold). An increase in hydrogen ion concentration ([H+]) is approximately concurrent with elevation of blood lactate and CO 2 output during exercise. Near-infrared spectra (NIRS) and invasive interstitial fluid pH (pHm) were measured in the flexor digitorum profundus during handgrip exercise to produce a mathematical model relating the two measures with an estimated error of 0.035 pH units. This NIRS pHm model was subsequently applied to spectra collected from the vastus lateralis of 10 subjects performing an incremental-intensity cycle protocol. Muscle oxygen saturation (SmO 2) was also calculated from spectra. We hypothesized that a H+ threshold could be identified for these subjects and that it would be different from but correlated with the LT. Lactate, gas exchange, SmO 2, and H+ thresholds were determined as a function of V̇o 2 using bilinear regression. LT was significantly different from both the gas exchange threshold (Δ = 0.27 ± 0.29 l/min) and H+ threshold (Δ = 0.29 ± 0.23 l/min), but the gas exchange threshold was not significantly different from the H+ threshold (Δ = 0.00 ± 0.38 l/min). The H+ threshold was strongly correlated with LT ( R 2 = 0.95) and the gas exchange threshold ( R 2 = 0.85). This initial study demonstrates the feasibility of noninvasive pHm estimations, the determination of H+ threshold, and the relationship between H+ and classical metabolic thresholds during incremental exercise.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00849.2007

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Soller, B. R., Yang, Y., Lee, S. M. C., Wilson, C., & Hagan, R. D.
Venue
Journal of Applied Physiology
Published
2008-03
Volume
104
Issue
3
Pages
837-844
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2037169389
Cited by
29
References
5
FWCI
2.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.