Influence of blood flow occlusion on muscle oxygenation characteristics and the parameters of the power-duration relationship
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
It was previously (Monod H, Scherrer J. Ergonomics 8: 329–338, 1965) postulated that blood flow occlusion during exercise would reduce critical power (CP) to 0 Watts (W), while not altering the curvature constant (W′). We empirically assessed the influence of blood flow occlusion on CP, W′, and muscle oxygenation characteristics. Ten healthy men (age: 24.8 ± 2.6 yr; height: 180 ± 5 cm; weight: 84.6 ± 10.1 kg) completed four constant-power handgrip exercise tests during both control blood flow (control) and blood flow occlusion (occlusion) for the determination of the power-duration relationship. Occlusion CP (−0.7 ± 0.4 W) was significantly ( P < 0.001) lower than control CP (4.1 ± 0.7 W) and significantly ( P < 0.001) lower than 0 W. Occlusion W′ (808 ± 155 J) was significantly ( P < 0.001) different from control W′ (558 ± 129 J), and all 10 subjects demonstrated an increased occlusion W′ with a mean increase of ∼49%. The present findings support the aerobic nature of CP. The findings also demonstrate that the amount of work that can be performed above CP is constant for a given condition, but can vary across conditions. Moreover, this amount of work that can be performed above CP does not appear to be the determinant of W′, but rather a consequence of the depletion of intramuscular energy stores and/or the accumulation of fatigue-inducing metabolites, which limit exercise tolerance and determine W′.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669 · cited 1×
“The deoxy[Hb Mb] is relatively insensitive to changes in blood volume (10, 19, 22) and has been used to reliably estimate the fractional oxygen extraction (10, 13, 14, 19, 20, 22, 34).”
MethodMyoglobin O2 desaturation during exercise. Evidence of limited O2 transport.
Richardson, R. S., Noyszewski, E. A., Kendrick, K. F., Leigh, J. S., & Wagner, P. D. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118237 · Cited by 647
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Determinants of maximal oxygen transport and utilization
Wagner, P. D. (1996) · Annual Review of Physiology · doi:10.1146/annurev.ph.58.030196.000321 · Cited by 421 · cited 5×
“These constraints directly impact aerobic energy production, thus dictating maximum V̇O2 (44, 53, 54) and presumably CP (4, 12, 39, 51).”
BackgroundInfluentialLactic acidosis as a facilitator of oxyhemoglobin dissociation during exercise
Stringer, W., Wasserman, K., Casaburi, R., Porszasz, J., Maehara, K., & French, W. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.4.1462 · Cited by 187
Sánchez-Lavega, A., & Salazar, A. (1994) · Journal of Applied Physics · doi:10.1063/1.357720 · Cited by 58
Attenuation of Muscle Deoxygenation Precedes EMG Threshold in Normoxia and Hypoxia
OSAWA, T., KIME, R., HAMAOKA, T., KATSUMURA, T., & YAMAMOTO, M. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182100261 · Cited by 46
Cited by
Critical Power: An Important Fatigue Threshold in Exercise Physiology
POOLE, D. C., BURNLEY, M., VANHATALO, A., ROSSITER, H. B., & JONES, A. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000939 · Cited by 535
Ansdell, P., Thomas, K., Hicks, K. M., Hunter, S. K., Howatson, G., & Goodall, S. (2020) · Experimental Physiology · doi:10.1113/ep088548 · Cited by 403
“…to terminate once W′ is fully utilized and a ‘critical’ degree of metabolic disturbance within the exercising musculature is attained (Burnley & Jones, 2018; Jones et al., 2008; Vanhatalo et al., 2010), an interpretation that explains single-limb exercise tolerance (Broxterman et al., 2015).”
BackgroundJones, A. M., & Vanhatalo, A. (2017) · Sports Medicine · doi:10.1007/s40279-017-0688-0 · Cited by 259
“This reciprocity between CP and W0 has also been reported following endurance training interventions [20, 24], with the breathing of hypoxic and hyperoxic gas mixtures [13, 42], and during blood flow occlusion [50].”
BackgroundCraig, J. C., Broxterman, R. M., Wilcox, S. L., Chen, C., & Barstow, T. J. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00207.2017 · Cited by 95
“Still, the forearm has been shown to adhere to the parameters of the power-duration relationship (7, 8), a robust description of performance and fatigue that integrates aerobic and anaerobic components across multiple physiological systems (39), in the same way as whole body or lower limb exercise.”
BackgroundSelf-citationClark, I. E., Vanhatalo, A., Thompson, C., Joseph, C., Black, M. I., Blackwell, J. R., Wylie, L. J., Tan, R., Bailey, S. J., Wilkins, B. W., et al. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00207.2019 · Cited by 75
“The physiological mechanisms underpinning W′ have not been entirely resolved (5, 33, 43).”
BackgroundOral taurine improves critical power and severe-intensity exercise tolerance
Waldron, M., Patterson, S. D., & Jeffries, O. (2019) · Amino Acids · doi:10.1007/s00726-019-02775-6 · Cited by 34
Metadata
- Authors
- Broxterman, R. M., Ade, C. J., Craig, J. C., Wilcox, S. L., Schlup, S. J., & Barstow, T. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2015-04-01
- Volume
- 118
- Issue
- 7
- Pages
- 880-889
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1972856038
- Cited by
- 61
- References
- 7
- FWCI
- 13.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.