The DOI matches its Crossref record.
Human pulmonary vascular response to 4 h of hypercapnia and hypocapnia measured using Doppler echocardiography
Abstract
Hypercapnia has been shown in animal experiments to induce pulmonary hypertension. This study measured the sensitivity and time course of the human pulmonary vascular response to sustained (4 h) hypercapnia and hypocapnia. Twelve volunteers undertook three protocols: 1) 4-h euoxic (end-tidal Po 2 = 100 Torr) hypercapnia (end-tidal Pco 2 was 10 Torr above normal), followed by 2 h of recovery with euoxic eucapnia; 2) 4-h euoxic hypocapnia (end-tidal Pco 2 was 10 Torr below normal) followed by 2 h of recovery; and 3) 6-h air breathing (control). Pulmonary vascular resistance was assessed at 0.5- to 1-h intervals by using Doppler echocardiography via the maximum tricuspid pressure gradient during systole. Results show progressive changes in pressure gradient over 1–2 h after the onset or offset of the stimuli, and sensitivities of 0.6 to 1 Torr change in pressure gradient per Torr change in end-tidal Pco 2. The human pulmonary circulatory response to changes in Pco 2 has a slower time course and greater sensitivity than is commonly assumed. Vascular tone in the normal pulmonary circulation is substantial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
BTS guideline for emergency oxygen use in adult patients
O'Driscoll, B. R., Howard, L. S., Davison, A. G., & on behalf of the British Thoracic Society (2008) · Thorax · doi:10.1136/thx.2008.102947 · Cited by 729
Hypoxic Pulmonary Vasoconstriction
Sylvester, J. T., Shimoda, L. A., Aaronson, P. I., & Ward, J. P. T. (2012) · Physiological Reviews · doi:10.1152/physrev.00041.2010 · Cited by 725
BTS guideline for oxygen use in adults in healthcare and emergency settings
O'Driscoll, B. R., Howard, L. S., Earis, J., & Mak, V (2017) · Thorax · doi:10.1136/thoraxjnl-2016-209729 · Cited by 679
Mekontso Dessap, A., Boissier, F., Charron, C., Bégot, E., Repessé, X., Legras, A., Brun-Buisson, C., Vignon, P., & Vieillard-Baron, A. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4141-2 · Cited by 550
Price, L. C., Wort, S. J., Finney, S. J., Marino, P. S., & Brett, S. J. (2010) · Critical Care · doi:10.1186/cc9264 · Cited by 389
Hypoxic Pulmonary Vasoconstriction: Physiology and Anesthetic Implications
Lumb, A. B., & Slinger, P. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000569 · Cited by 306
Prone Positioning Unloads the Right Ventricle in Severe ARDS
Vieillard-Baron, A., Charron, C., Caille, V., Belliard, G., Page, B., & Jardin, F. (2007) · Chest · doi:10.1378/chest.07-1013 · Cited by 280
Positive pressure ventilation in the cardiac intensive care unit
Alviar, C. L., Miller, P. E., McAreavey, D., Katz, J. N., Lee, B., Moriyama, B., Soble, J., van Diepen, S., Solomon, M. A., & Morrow, D. A. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.06.074 · Cited by 271
Mutation of von Hippel–Lindau Tumour Suppressor and Human Cardiopulmonary Physiology
Smith, T. G., Brooks, J. T., Balanos, G. M., Lappin, T. R., Layton, D. M., Leedham, D. L., Liu, C., Maxwell, P. H., McMullin, M. F., McNamara, C. J., et al. (2006) · PLoS Medicine · doi:10.1371/journal.pmed.0030290 · Cited by 182
Self-citation
Metadata
- Authors
- Balanos, G. M., Talbot, N. P., Dorrington, K. L., & Robbins, P. A.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2003-04-01
- Volume
- 94
- Issue
- 4
- Pages
- 1543-1551
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2119342959
- Cited by
- 183
- References
- 0
- FWCI
- 2.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.