Noninvasive assessment of sympathetic vasoconstriction in human and rodent skeletal muscle using near-infrared spectroscopy and Doppler ultrasound
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The precise role of the sympathetic nervous system in the regulation of skeletal muscle blood flow during exercise has been challenging to define in humans, partly because of the limited techniques available for measuring blood flow in active muscle. Recent studies using near-infrared (NIR) spectroscopy to measure changes in tissue oxygenation have provided an alternative method to evaluate vasomotor responses in exercising muscle, but this approach has not been fully validated. In this study, we tested the hypothesis that sympathetic activation would evoke parallel changes in tissue oxygenation and blood flow in resting and exercising muscle. We simultaneously measured tissue oxygenation with NIR spectroscopy and blood flow with Doppler ultrasound in skeletal muscle of conscious humans ( n = 13) and anesthetized rats ( n = 9). In resting forearm of humans, reflex activation of sympathetic nerves with the use of lower body negative pressure produced graded decreases in tissue oxygenation and blood flow that were highly correlated ( r = 0.80, P < 0.0001). Similarly, in resting hindlimb of rats, electrical stimulation of sympathetic nerves produced graded decreases in tissue oxygenation and blood flow velocity that were highly correlated ( r = 0.93, P < 0.0001). During rhythmic muscle contraction, the decreases in tissue oxygenation and blood flow evoked by sympathetic activation were significantly attenuated ( P < 0.05 vs. rest) but remained highly correlated in both humans ( r = 0.80, P < 0.006) and rats ( r = 0.92, P < 0.0001). These data indicate that, during steady-state metabolic conditions, changes in tissue oxygenation can be used to reliably assess sympathetic vasoconstriction in both resting and exercising skeletal muscle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 1×
“In the human subjects, day-to-day repeatability of the tissue oxygenation and blood flow responses to LBNP was assessed by using Bland-Altman comparison methods of agreement (3).”
MethodMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669 · cited 2×
“Because NIR spectroscopy measures changes in oxygenation mainly in the microcirculation (16), the decreases in the NIR signals observed during sympathetic activation should primarily reflect arteriolar, not venular, constriction.”
BackgroundComparison of femoral blood gases and muscle near-infrared spectroscopy at exercise onset in humans
MacDonald, M. J., Tarnopolsky, M. A., Green, H. J., & Hughson, R. L. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.2.687 · Cited by 98 · cited 1×
“For example, tissue oxygenation and muscle blood flow likely are dissociated at the onset of dynamic exercise when both oxygen demand and delivery are increasing, just as venous oxygen saturation and muscle blood flow are dissociated (15).”
Background
Cited by
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Rosenmeier, J. B., Hansen, J., & González‐Alonso, J. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2004.063107 · Cited by 195
“However, there is also abundant evidence that this sympathetic control can be attenuated or even abolished in contracting muscle (Remensnyder et al. 1962; Thomas et al. 1994; Hansen et al. 1996; Ruble et al. 2002; Tschakovsky et al. 2002; Rosenmeier et al. 2003a; Wray et al. 2004; Fadel et al. 2004).”
BackgroundDavis, S. L., Fadel, P. J., Cui, J., Thomas, G. D., & Crandall, C. G. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00867.2005 · Cited by 179
“, handgrip), skin blood flow likely remained low and had minimal influence on tissue oxygenation (4, 8, 12).”
BackgroundMethodInfluentialSelf-citationHoriuchi, M., Endo, J., Dobashi, S., Handa, Y., Kiuchi, M., & Koyama, K. (2017) · Physiological Reports · doi:10.14814/phy2.13475 · Cited by 19
“Moreover, our results may indicate that sympathetic vasoconstriction was augmented by BR supplementation, as reductions in tissue oxygenation have been shown to be an indicator of sympathetic vasoconstriction with acute sympathetic stimulation during small muscle exercise (Hansen et al. 1996; Fadel et al. 2004; Horiuc…”
BackgroundMethodInfluential
Metadata
- Authors
- Fadel, P. J., Keller, D. M., Watanabe, H., Raven, P. B., & Thomas, G. D.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2004-04
- Volume
- 96
- Issue
- 4
- Pages
- 1323-1330
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2127450918
- Cited by
- 108
- References
- 4
- FWCI
- 14.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive assessment of sympathetic vasoconstriction in human and rodent skeletal muscle using near-infrared spectroscopy and Doppler ultrasound. https://app.cochat.ai/papers/10.1152/japplphysiol.01041.2003
- The paper
- Fadel, P. J., Keller, D. M., Watanabe, H., Raven, P. B., & Thomas, G. D. (2004). Noninvasive assessment of sympathetic vasoconstriction in human and rodent skeletal muscle using near-infrared spectroscopy and Doppler ultrasound. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.01041.2003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.