CoChat

Effects of caffeine and acute exercise on the validity of a submaximal cycle ergometer test: a randomised, placebo-controlled crossover study

Open access
Björkman, Frida, Engström, Jessica, Helge, Torbjörn, Ekblom, Örjan · 2026 · European Journal of Applied Physiology

The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index; 2 of the 15 sources its claims cite were checked for support.

Abstract

Purpose: To investigate the effects of caffeine (Caf) consumption and prior exercise on the validity of the Ekblom–Bak cycle test (EB-test) for estimating maximal oxygen uptake (VO₂max). Methods: Healthy, habitual caffeine users received 250 mg Caf or placebo (Pla) in a double-blind randomised crossover design separated by one week. Each visit included two EB-tests performed before and after a maximal treadmill exercise (Ex). Heart rate (HR), blood pressure (BP), and oxygen uptake were measured, and estimation error was calculated as estimated–measured VO₂max. Data were analysed using repeated measures ANOVA with condition (Caf, Pla) and time (pre-Ex, post-Ex) as within-subject factors. Results: Participants were 15 women and 17 men (33.5 ± 11.1 years). Resting HR and BP did not differ between trials, except for a modest increase in systolic BP after Caf (129 ± 14 mmHg vs. 122 ± 15 mmHg; p = 0.042). Maximal HR and VO₂max were unaffected, but time to exhaustion increased with caffeine (438 ± 73 s vs. 415 ± 69 s; p = 0.012). HR increased significantly from pre- to post-Ex, with no differences between Caf and Pla conditions. Estimation errors rose from pre- to post-Ex (–0.17 and − 0.12 L·min⁻¹ to − 0.28 and − 0.30 L·min⁻¹), independent of caffeine intake, body mass, or measured VO₂max. Conclusion: Caffeine did not affect the accuracy of the VO₂max estimation from the EB-test. However, strenuous exercise before testing increased estimation errors, suggesting that recent intense exercise has a greater impact on EB-test validity than moderate caffeine consumption.

Overview

CoChat Summary

TL;DR

In healthy habitual caffeine users, 250 mg caffeine did not affect the accuracy of VO₂max estimation from the Ekblom–Bak cycle test, but strenuous exercise before testing increased submaximal heart rate and caused systematic underestimation of VO₂max. Caffeine increased time to exhaustion but did not change measured VO₂max or maximal heart rate.

Key findings

  • Caffeine did not significantly affect heart rate or estimated VO₂max compared with placebo. Estimation errors rose from pre- to post-exercise: −0.17 and −0.12 L·min⁻¹ to −0.28 and −0.30 L·min⁻¹, independent of caffeine intake, body mass, or measured VO₂max.
  • Prior strenuous exercise produced a significant time effect: post-exercise heart rate increased 13–27%, resulting in approximately 5% greater underestimation of VO₂max regardless of caffeine or placebo. Mean estimation-error change was −0.11 L·min⁻¹ in the placebo condition and −0.18 L·min⁻¹ in the caffeine condition, with no difference between conditions.
  • Caffeine increased time to exhaustion (438 ± 73 s vs. 415 ± 69 s; p = 0.012), while measured VO₂max (3.81 ± 0.94 vs. 3.81 ± 0.93 L·min⁻¹) and maximal heart rate (187 ± 13 vs. 188 ± 12 bpm) were unaffected. Resting systolic blood pressure showed a modest increase after caffeine (129 ± 14 mmHg vs. 122 ± 15 mmHg; p = 0.042).
  • Equivalence testing indicated that differences in estimation errors fell outside the predefined equivalence bounds of ±0.1 L·min⁻¹, so small caffeine-induced changes could not be confidently ruled out.

Methods

  • Double-blind, randomised, placebo-controlled crossover study separated by one week. Thirty-two habitual caffeine users volunteered (15 women and 17 men; 33.5 ± 11.1 years); four withdrew, and 28 completed (13 received caffeine first, 15 received placebo first). Participants received 250 mg caffeine or placebo (50 µg vitamin D) after baseline measurements.
  • Each visit included two Ekblom–Bak cycle tests, before and after a maximal treadmill exercise test. The EB-test comprised 4 min at ~30 W followed by 4 min at a higher individually prescribed work rate; heart rate was averaged over the final minute at each work rate, and VO₂max was estimated using sex-specific prediction equations. The maximal treadmill test measured VO₂max with a Jaeger Oxycon Pro metabolic system; a 30-minute rest separated it from the second EB-test.
  • Analysis used two-way repeated-measures ANOVA with condition (caffeine, placebo) and time (pre-exercise, post-exercise) as within-subject factors, Tukey post hoc comparisons, equivalence testing via two one-sided tests with ±0.1 L·min⁻¹ bounds, and repeated-measures ANCOVA with body mass and measured VO₂max as covariates. Analyses were performed in Jamovi, with significance set at p < 0.05.

Limitations

  • The paper states that blinding was not fully maintained: 12 of 28 included participants spontaneously reported believing they were in the caffeine condition; all such reports occurred during caffeine sessions and were correct, so expectancy effects may have influenced some outcomes.
  • The paper states the study was underpowered: the power calculation indicated 37 participants were required, but only 28 were enrolled due to recruitment challenges and dropouts. Small physiological changes may have gone undetected, and equivalence testing could not confirm that caffeine-related differences were negligible within ±0.1 L·min⁻¹.
  • The paper states that only one caffeine dose and one type of submaximal test were used, in healthy physically active individuals, and that strenuous prior exercise followed by a short recovery period is an extreme scenario; results may differ with other doses, populations, or protocols. Evident from the text: the abstract reports 15 women and 17 men, while the results report 28 completers after four withdrawals, so the participant count is inconsistent across sections.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1007/s00421-026-06182-0

Cites

48 of 48 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Timeline of experimental procedures. Ex; exercise, EB-test; Ekblom-Bak test, HR; heart rate, BP; blood pressure, RPE; ratings of perceived exertion, VO2max; maximal oxygen uptake
Fig. 1 Timeline of experimental procedures. Ex; exercise, EB-test; Ekblom-Bak test, HR; heart rate, BP; blood pressure, RPE; ratings of perceived exertion, VO2max; maximal oxygen uptakeCC BY · PubMed Central
Fig. 2 Estimated marginal means of estimation error across conditions (caffeine vs. placebo) and time points (pre- and post-exercise), derived from a repeated-measures ANOVA. Error bars represent 95% confidence intervals
Fig. 2 Estimated marginal means of estimation error across conditions (caffeine vs. placebo) and time points (pre- and post-exercise), derived from a repeated-measures ANOVA. Error bars represent 95% confidence intervalsCC BY · PubMed Central

Verification

Claims the paper makes

2 Valid · 0 Not valid · 8 Not checked · 35 Own results and interpretations

13 more claims

Create a free account to see all 45 claims and to verify the 13 references still open.

See all claims — free account
  • It may state two separate claims as one. 19
  • The quote only partly states this claim. 2
  • Probably not a substantial claim. 13

Create a free account to see these claims.

Statistics recomputed

Every reported test result, recomputed from its test statistic and degrees of freedom. A result shows as not adding up only once an independent check has confirmed it.

  • Consistentt(27) = 2.82reported p < .01 · recomputed p = .009

    “t(27) = 2.82, p < .01”

  • Consistentt(27) = -0.85reported p = .2 · recomputed p = .403

    “t(27) = -0.85, p = .20”

    The paper states a one-tailed test

  • Consistentt(27) = 1.54reported p = .067 · recomputed p = .135

    “t(27) = 1.54, p = .067”

    The paper states a one-tailed test

  • Consistentt(27) = -2.16reported p = .02 · recomputed p = .040

    “t(27) = -2.16, p = .02”

    The paper states a one-tailed test

  • ConsistentF(1, 25) = 0.001reported p = .981 · recomputed p = .975

    “F(1, 25) = 0.001, p = .981”

5 of 7 · the rest aren’t loaded

2 more recomputed tests

Create a free account to see every test the Stats check recomputed.

See all tests — free account

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

4 of 4

Citations

Cites

Show all 48 references

Metadata

Authors
Björkman, F., Engström, J., Helge, T., & Ekblom, Ö.
Affiliations
Swedish School of Sport and Health Sciences (SE)
Corresponding author
Björkman, Frida
Venue
European Journal of Applied Physiology
Published
2026-02-28
Volume
126
Issue
6
Pages
3461-3471
ISSN
  • 0020-9376 (ISSN-L)
  • 1439-6319
  • 1439-6327
OpenAlex
W7132842391
Cited by
0
References
48
FWCI
0.00
Type
journal article
Language
en
Open access
Licence
Locations
  • European Journal of Applied Physiology (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Högskolan Kristianstad Publikationer (submittedVersion, other-oa)
Funders
Swedish School of Sport and Health Sciences
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Pharmacology (medical) › Coffee research and impacts
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
Keywords
caffeine, acute exercise, VO2max prediction, test validity, estimation error, time to exhaustion, blood pressure, heart rate, VO2max
MeSH terms
Adult, Central Nervous System Stimulants, Blood Pressure, Caffeine, Double-Blind Method, Exercise Test, Female, Heart Rate, Humans, Male, Oxygen Consumption, Reproducibility of Results, Exercise, Cross-Over Studies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (qwen3.8-omni-flash and gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of caffeine and acute exercise on the validity of a submaximal cycle ergometer test: a randomised, placebo-controlled crossover study. https://app.cochat.ai/papers/10.1007/s00421-026-06182-0
The paper
Björkman, F., Engström, J., Helge, T., & Ekblom, Ö. (2026). Effects of caffeine and acute exercise on the validity of a submaximal cycle ergometer test: a randomised, placebo-controlled crossover study. European Journal of Applied Physiology. https://doi.org/10.1007/s00421-026-06182-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.