Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 227

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Atrophic rhinitis: a CFD study of air conditioning in the nasal cavity

Garcia, Guilherme J. M., Bailie, Neil, Martins, Dário A., Kimbell, Julia S.·2007·Journal of Applied Physiology

Abstract

Atrophic rhinitis is a chronic disease of the nasal mucosa. The disease is characterized by abnormally wide nasal cavities, and its main symptoms are dryness, crusting, atrophy, fetor, and a paradoxical sensation of nasal congestion. The etiology of the disease remains unknown. Here, we propose that excessive evaporation of the mucous layer is the basis for the relentless nature of this disease. Airflow and water and heat transport were simulated using computational fluid dynamics (CFD) techniques. The nasal geometry of an atrophic rhinitis patient was acquired from computed tomography scans before and after a procedure to narrow the nasal cavity. Simulations of air conditioning in the atrophic nose were compared with similar computations performed within the nasal geometries of four healthy humans. The excessively wide cavity of the patient generated abnormal flow patterns, which led to abnormal patterns of water fluxes across the wall. Geometrically, the atrophic nose had a much lower surface area than the healthy nasal passages, which increased water fluxes per unit area. Nevertheless, the simulations indicated that the atrophic nose did not condition inspired air as effectively as the healthy geometries. These simulations of water transport in the nasal cavity are consistent with the hypothesis that excessive evaporation of mucus plays a key role in the pathophysiology of atrophic rhinitis. We conclude that the main goals of a surgery to treat atrophic rhinitis should be 1) to restore the original surface area of the nose, 2) to restore the physiological airflow distribution, and 3) to create symmetric cavities.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.01118.2006

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 227

Metadata

Authors
Garcia, G. J. M., Bailie, N., Martins, D. A., & Kimbell, J. S.
Venue
Journal of Applied Physiology
Published
2007-09
Volume
103
Issue
3
Pages
1082-1092
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2051596208
Cited by
227
References
1
FWCI
9.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Atrophic rhinitis: a CFD study of air conditioning in the nasal cavity. https://app.cochat.ai/papers/10.1152/japplphysiol.01118.2006
The paper
Garcia, G. J. M., Bailie, N., Martins, D. A., & Kimbell, J. S. (2007). Atrophic rhinitis: a CFD study of air conditioning in the nasal cavity. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.01118.2006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.