Reducing the time period of steady state does not affect the accuracy of energy expenditure measurements by indirect calorimetry
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Achievement of steady state during indirect calorimetry measurements of resting energy expenditure (REE) is necessary to reduce error and ensure accuracy in the measurement. Steady state is often defined as 5 consecutive min (5-min SS) during which oxygen consumption and carbon dioxide production vary by ±10%. These criteria, however, are stringent and often difficult to satisfy. This study aimed to assess whether reducing the time period for steady state (4-min SS or 3-min SS) produced measurements of REE that were significantly different from 5-min SS. REE was measured with the use of open-circuit indirect calorimetry in 39 subjects, of whom only 21 (54%) met the 5-min SS criteria. In these 21 subjects, median biases in REE between 5-min SS and 4-min SS and between 5-min SS and 3-min SS were 0.1 and 0.01%, respectively. For individuals, 4-min SS measured REE within a clinically acceptable range of ±2% of 5-min SS, whereas 3-min SS measured REE within a range of −2–3% of 5-min SS. Harris-Benedict prediction equations estimated REE for individuals within ±20–30% of 5-min SS. Reducing the time period of steady state to 4 min produced measurements of REE for individuals that were within clinically acceptable, predetermined limits. The limits of agreement for 3-min SS fell outside the predefined limits of ±2%; however, both 4-min SS and 3-min SS criteria greatly increased the proportion of subjects who satisfied steady state within smaller limits than would be achieved if relying on prediction equations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
New methods for calculating metabolic rate with special reference to protein metabolism
Weir, J. B. D. V. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004363 · Cited by 5,603
A new predictive equation for resting energy expenditure in healthy individuals
Mifflin, M., St Jeor, S., Hill, L., Scott, B., Daugherty, S., & Koh, Y. (1990) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/51.2.241 · Cited by 2,544
Predicting Energy Requirements in the Clinical Setting: Are Current Methods Evidence Based?
Reeves, M. M., & Capra, S. (2003) · Nutrition Reviews · doi:10.1301/nr.2003.apr.143-151 · Cited by 97
Self-citation
Cited by
Fullmer, S., Benson-Davies, S., Earthman, C. P., Frankenfield, D. C., Gradwell, E., Lee, P. S. P., Piemonte, T., & Trabulsi, J. (2015) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2015.04.003 · Cited by 228
Indirect calorimetry: methodology, instruments and clinical application
da Rocha, E. E. M., Alves, V. G. F., & da Fonseca, R. B. V. (2006) · Current Opinion in Clinical Nutrition and Metabolic Care · doi:10.1097/01.mco.0000222107.15548.f5 · Cited by 177
LEAP2 reduces postprandial glucose excursions and ad libitum food intake in healthy men
Hagemann, C. A., Jensen, M. S., Holm, S., Gasbjerg, L. S., Byberg, S., Skov-Jeppesen, K., Hartmann, B., Holst, J. J., Dela, F., Vilsbøll, T., et al. (2022) · Cell Reports Medicine · doi:10.1016/j.xcrm.2022.100582 · Cited by 81
Schrack, J. A., Simonsick, E. M., & Ferrucci, L. (2010) · PLoS ONE · doi:10.1371/journal.pone.0009292 · Cited by 66
Metadata
- Authors
- Reeves, M. M., Davies, P. S. W., Bauer, J., & Battistutta, D.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2004-07
- Volume
- 97
- Issue
- 1
- Pages
- 130-134
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1546229139
- Cited by
- 95
- References
- 4
- FWCI
- 3.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.