Abstract
Cardiopulmonary exercise testing for peak oxygen uptake (V̇o 2peak) can evaluate prognosis in chronic heart failure (CHF) patients, with the peak respiratory exchange ratio (RER peak) commonly used to confirm maximal effort and maximal oxygen uptake (V̇o 2max). We determined the precision of RER peak in confirming V̇o 2max, and whether a novel ramp-incremental (RI) step-exercise (SE) (RISE) test could better determine V̇o 2max in CHF. Male CHF patients ( n = 24; NYHA class I–III) performed a symptom-limited RISE-95 cycle ergometer test in the format: RI (4–18 W/min; ∼10 min); 5 min recovery (10 W); SE (95% peak RI work rate). Patients ( n = 18) then performed RISE-95 tests using slow (3–8 W/min; ∼15 min) and fast (10–30 W/min; ∼6 min) ramp rates. Pulmonary gas exchange was measured breath-by-breath. V̇o 2peak was compared within patients by unpaired t-test of the highest 12 breaths during RI and SE phases to confirm V̇o 2max and its 95% confidence limits (CI 95). RER peak was significantly influenced by ramp rate (fast, medium, slow: 1.21 ± 0.1 vs. 1.15 ± 0.1 vs. 1.09 ± 0.1; P = 0.001), unlike V̇o 2peak (mean n = 18; 14.4 ± 2.6 ml·kg−1·min−1; P = 0.476). Group V̇o 2peak was similar between RI and SE ( n = 24; 14.5 ± 3.0 vs. 14.7 ± 3.1 ml·kg−1·min−1; P = 0.407); however, within-subject comparisons confirmed V̇o 2max in only 14 of 24 patients (CI 95 for V̇o 2max estimation averaged 1.4 ± 0.8 ml·kg−1·min−1). The RER peak in CHF was significantly influenced by ramp rate, suggesting its use to determine maximal effort and V̇o 2max be abandoned. In contrast, the RISE-95 test had high precision for V̇o 2max confirmation with patient-specific CI 95 (without secondary criteria), and showed that V̇o 2max is commonly underestimated in CHF. The RISE-95 test was well tolerated by CHF patients, supporting its use for V̇o 2max confirmation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exercise capacity and mortality among men referred for exercise testing
Myers, J., Prakash, M., Froelicher, V., Do, D., Partington, S., & Atwood, J. E. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa011858 · Cited by 4,114
O'Connor (2009) · doi:10.1001/jama.2009.454 · Cited by 2,173 · cited 3×
“Our findings are also consistent with the notion that peak exercise testing is safe and well tolerated by CHF patients (28), and even suggests repeated peak efforts may be safely performed after only a few minutes of active recovery.”
InfluentialGibbons, R. J., Balady, G. J., Beasley, J. W., FAAFP, Bricker, J. T., Duvernoy, W. F. C., Froelicher, V. F., Mark, D. B., Marwick, T. H., McCallister, B. D., et al. (1997) · Circulation · doi:10.1161/01.cir.96.1.345 · Cited by 1,094
Arena, R., Myers, J., Williams, M. A., Gulati, M., Kligfield, P., Balady, G. J., Collins, E., & Fletcher, G. (2007) · Circulation · doi:10.1161/circulationaha.106.184461 · Cited by 727
Sullivan, M. J., Higginbotham, M. B., & Cobb, F. R. (1988) · Circulation · doi:10.1161/01.cir.78.3.506 · Cited by 697
(1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00150-2 · Cited by 448
Determinants of maximal oxygen transport and utilization
Wagner, P. D. (1996) · Annual Review of Physiology · doi:10.1146/annurev.ph.58.030196.000321 · Cited by 421
Mezzani, A., Agostoni, P., Cohen-Solal, A., Corrà, U., Jegier, A., Kouidi, E., Mazic, S., Meurin, P., Piepoli, M., Simon, A., et al. (2009) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e32832914c8 · Cited by 402 · cited 4×
“However, and in contrast to recommended CHF guidelines (2, 3, 12, 22, 29), our findings suggest that the RERpeak is inappropriate for confirming maximal effort and V̇O2max.”
Influential
Cited by
Measurement of the maximum oxygen uptake V̇ o 2max : V̇ o 2peak is no longer acceptable
Poole, D. C., & Jones, A. M. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01063.2016 · Cited by 533
Hansen, D., Abreu, A., Ambrosetti, M., Cornelissen, V., Gevaert, A., Kemps, H., Laukkanen, J. A., Pedretti, R., Simonenko, M., Wilhelm, M., et al. (2022) · European Journal of Preventive Cardiology · doi:10.1093/eurjpc/zwab007 · Cited by 321
The anaerobic threshold: 50+ years of controversy
Poole, D. C., Rossiter, H. B., Brooks, G. A., & Gladden, L. B. (2021) · The Journal of Physiology · doi:10.1113/jp279963 · Cited by 312
“However, it is important to note that GET occurs at the same V̇O2 whether the ramp is rapid (completed within 5 min) or slower (completed within 10–15 min) (Agostoni et al. 2005; Bowen et al. 2012).”
BackgroundSelf-citationIdentification of Non-Invasive Exercise Thresholds: Methods, Strategies, and an Online App
Keir, D. A., Iannetta, D., Mattioni Maturana, F., Kowalchuk, J. M., & Murias, J. M. (2022) · Sports Medicine · doi:10.1007/s40279-021-01581-z · Cited by 193
Metadata
- Authors
- Bowen, T. S., Cannon, D. T., Begg, G., Baliga, V., Witte, K. K., & Rossiter, H. B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2012-08-01
- Volume
- 113
- Issue
- 3
- Pages
- 451-458
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2013101941
- Cited by
- 48
- References
- 8
- FWCI
- 5.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A novel cardiopulmonary exercise test protocol and criterion to determine maximal oxygen uptake in chronic heart failure. https://app.cochat.ai/papers/10.1152/japplphysiol.01416.2011
- The paper
- Bowen, T. S., Cannon, D. T., Begg, G., Baliga, V., Witte, K. K., & Rossiter, H. B. (2012). A novel cardiopulmonary exercise test protocol and criterion to determine maximal oxygen uptake in chronic heart failure. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.01416.2011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.