Does fitness level modulate the cardiovascular hemodynamic response to exercise?
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Subjects with greater aerobic fitness demonstrate better diastolic compliance at rest, but whether fitness modulates exercise cardiac compliance and cardiac filling pressures remains to be determined. On the basis of maximal oxygen consumption (V̇o 2max), healthy male subjects were categorized into either low (LO: V̇o 2max = 43 ± 6 ml·kg−1·min−1; n = 3) or high (HI: V̇o 2max = 60 ± 3 ml·kg−1·min−1; n = 5) aerobic power. Subjects performed incremental cycle exercise to 90% V̇o 2max. Right atrial (RAP) and pulmonary artery wedge (PAWP) pressures were measured, and left ventricular (LV) transmural filling pressure (TMFP = PAWP − RAP) was calculated. Cardiac output (CO) and stroke volume (SV) were determined by direct Fick, and LV end-diastolic volume (EDV) was estimated from echocardiographic fractional area change and Fick SV. There were no between-group differences for any measure at rest. At a submaximal workload of 150 W, PAWP and TMFP were higher ( P < 0.05) in LO compared with HI (12 vs. 8 mmHg, and 9 vs. 4 mmHg, respectively). At peak exercise, CO, SV, and EDV were lower in LO ( P < 0.05). RAP was not different at peak exercise, but PAWP (23 vs. 15 mmHg) and TMFP (12 vs. 6 mmHg) were higher in LO ( P < 0.05). Compared with less fit subjects, subjects with greater aerobic fitness demonstrated lower LV filling pressures during exercise, whereas SV and EDV were either similar (submaximal exercise) or higher (peak exercise), suggesting superior diastolic function and compliance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cardiac output during submaximal and maximal work
Åstrand, P.-O., Cuddy, T. E., Saltin, B., & Stenberg, J. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.2.268 · Cited by 722 · cited 1×
“exercise is due solely to the increase in heart rate (HR) (2).”
BackgroundEffect of Aging and Physical Activity on Left Ventricular Compliance
Arbab-Zadeh, A., Dijk, E., Prasad, A., Fu, Q., Torres, P., Zhang, R., Thomas, J. D., Palmer, D., & Levine, B. D. (2004) · Circulation · doi:10.1161/01.cir.0000142863.71285.74 · Cited by 535 · cited 1×
“Levine and colleagues reported that both younger (12) and older (1) endurance-trained athletes had greater resting diastolic compliance during cardiac volume loading (rapid infusion of saline) and unloading (lower body negative pressure).”
Background
Cited by
Haykowsky, M. J., Brubaker, P. H., John, J. M., Stewart, K. P., Morgan, T. M., & Kitzman, D. W. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.02.055 · Cited by 447
Self-citationPulmonary Vascular Hemodynamic Response to Exercise in Cardiopulmonary Diseases
Lewis, G. D., Bossone, E., Naeije, R., Grünig, E., Saggar, R., Lancellotti, P., Ghio, S., Varga, J., Rajagopalan, S., Oudiz, R., et al. (2013) · Circulation · doi:10.1161/circulationaha.112.000667 · Cited by 386
Cardiac Remodeling in Response to 1 Year of Intensive Endurance Training
Arbab-Zadeh, A., Perhonen, M., Howden, E., Peshock, R. M., Zhang, R., Adams-Huet, B., Haykowsky, M. J., & Levine, B. D. (2014) · Circulation · doi:10.1161/circulationaha.114.010775 · Cited by 364
Self-citationHaykowsky, M. J., Brubaker, P. H., Stewart, K. P., Morgan, T. M., Eggebeen, J., & Kitzman, D. W. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.02.055 · Cited by 358
Self-citationExercise-Induced Pulmonary Arterial Hypertension
Tolle, J. J., Waxman, A. B., Van Horn, T. L., Pappagianopoulos, P. P., & Systrom, D. M. (2008) · Circulation · doi:10.1161/circulationaha.108.787101 · Cited by 357
Persistent Exertional Intolerance After COVID-19
Singh, I., Joseph, P., Heerdt, P. M., Cullinan, M., Lutchmansingh, D. D., Gulati, M., Possick, J. D., Systrom, D. M., & Waxman, A. B. (2022) · CHEST · doi:10.1016/j.chest.2021.08.010 · Cited by 336
Goldberg, D. J., French, B., McBride, M. G., Marino, B. S., Mirarchi, N., Hanna, B. D., Wernovsky, G., Paridon, S. M., & Rychik, J. (2011) · Circulation · doi:10.1161/circulationaha.110.981746 · Cited by 295
Exercise-induced Pulmonary Hypertension: Physiological Basis and Methodological Concerns
Naeije, R., Vanderpool, R., Dhakal, B. P., Saggar, R., Saggar, R., Vachiery, J.-L., & Lewis, G. D. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201211-2090ci · Cited by 285
Budts, W., Borjesson, M., Chessa, M., van Buuren, F., Trigo Trindade, P., Corrado, D., Heidbuchel, H., Webb, G., Holm, J., & Papadakis, M. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht433 · Cited by 189
“Exercise is associated with an augmentation of the cardiac output, enhanced ventricular preload, and an increase in both the pulmonary and systemic arterial pressures.(23,24) Dynamic exercise imposes primarily a volume load, while static exercise produces primarily a pressure load.”
BackgroundLa Gerche, A., MacIsaac, A. I., Burns, A. T., Mooney, D. J., Inder, W. J., Voigt, J.-U., Heidbüchel, H., & Prior, D. L. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00457.2010 · Cited by 168
“(41) measured a similar increase in right and left atrial pressures during exercise suggesting they have limited influence on changes in transpulmonary pressure gradients.”
BackgroundThe effect of lifelong exercise dose on cardiovascular function during exercise.
Carrick-Ranson, G., Hastings, J. L., Bhella, P. S., Fujimoto, N., Shibata, S., Palmer, M. D., Boyd, K., Livingston, S., Dijk, E., & Levine, B. D. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00342.2013 · Cited by 146
Carrick-Ranson, G., Howden, E. J., Brazile, T. L., Levine, B. D., & Reading, S. A. (2023) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00798.2022 · Cited by 23
Metadata
- Authors
- Stickland, M. K., Welsh, R. C., Petersen, S. R., Tyberg, J. V., Anderson, W. D., Jones, R. L., Taylor, D. A., Bouffard, M., & Haykowsky, M. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2006-06
- Volume
- 100
- Issue
- 6
- Pages
- 1895-1901
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2141543150
- Cited by
- 138
- References
- 2
- FWCI
- 10.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.