Modified iodine-paper technique for the standardized determination of sweat gland activation
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Quantifying sweat gland activation provides important information when explaining differences in sweat rate between populations and physiological conditions. However, no standard technique has been proposed to measure sweat gland activation, while the reliability of sweat gland activation measurements is unknown. We examined the interrater and internal reliability of the modified-iodine paper technique, as well as compared computer-aided analysis to manual counts of sweat gland activation. Iodine-impregnated paper was pressed against the skin of 35 participants in whom sweating was elicited by exercise in the heat or infusion of methylcholine. The number of active glands was subsequently determined by computer-aided analysis. In total, 382 measurements were used to evaluate: 1) agreement between computer analysis and manual counts; 2) the interrater reliability of computer analysis between independent investigators; and 3) the internal reliability of sweat gland activation measurements between duplicate samples. The number of glands identified with computer analysis did not differ from manual counts (68 ± 29 vs. 72 ± 24 glands/cm 2; P = 0.27). These measures were highly correlated ( r = 0.77) with a mean bias ± limits of agreement of −4 ± 38 glands/cm 2. When comparing computer analysis measures between investigators, values were highly correlated ( r = 0.95; P < 0.001) and the mean bias ± limits of agreement was 4 ± 18 glands/cm 2. Finally, duplicate measures of sweat gland activation were highly correlated ( r = 0.88; P < 0.001) with a mean bias ± limits of agreement of 3 ± 29 glands/cm 2. These results favor the use of the modified-iodine paper technique with computer-aided analysis as a standard technique to reliably evaluate the number of active sweat glands.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Heat stress in older individuals and patients with common chronic diseases
Kenny, G. P., Yardley, J., Brown, C., Sigal, R. J., & Jay, O. (2010) · Canadian Medical Association Journal · doi:10.1503/cmaj.081050 · Cited by 771 · cited 1×
“physiological (23, 28, 38) and disease (24) states.”
Self-citationThe physiology, pharmacology, and biochemistry of the eccrine sweat gland
Sato, K. (1977) · Reviews of Physiology, Biochemistry and Pharmacology · doi:10.1007/bfb0037089 · Cited by 384
Sweat testing to evaluate autonomic function
Illigens, B. M. W., & Gibbons, C. H. (2009) · Clinical Autonomic Research · doi:10.1007/s10286-008-0506-8 · Cited by 255 · cited 1×
“Assessments of sweat gland activation have been used clinically to evaluate the extent of neurological damage caused by various disease states (13), as well as experimentally to evaluate sweat gland function in relation to exercise intensity (26), exercise training (8, 12), age (2, 14 –17, 21, 39), obesity (5), and se…”
BackgroundIndividual variations in structure and function of human eccrine sweat gland
Sato, K., & Sato, F. (1983) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1983.245.2.r203 · Cited by 215
Effect of physical training on peripheral sweat production
Buono, M. J., & Sjoholm, N. T. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.65.2.811 · Cited by 185
Inoue, Y., Tanaka, Y., Omori, K., Kuwahara, T., Ogura, Y., & Ueda, H. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1303-2 · Cited by 158 · cited 2×
“It is interesting to note that the calculated smallest detectable change is consistent with previous studies (5, 8, 14, 18, 26) reporting significant differences in sweat gland activation between var-”
BackgroundResultKONDO, TAKANO, AOKI, SHIBASAKI, TOMINAGA, & INOUE (1998) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.1998.00407.x · Cited by 130 · cited 3×
“glands/cm(2) during moderate intensity exercise in a hot (35– 49°C, 30–80% relative humidity) environment (12, 25, 26, 29).”
BackgroundResult
Cited by
Taylor, N. A., & Machado-Moreira, C. A. (2013) · Extreme Physiology & Medicine · doi:10.1186/2046-7648-2-4 · Cited by 490
“iodine, bromophenol blue) painted onto the skin or impregnated into paper which is then applied to the skin [64,74,75].”
BackgroundGlove-based sensors for multimodal monitoring of natural sweat
Bariya, M., Li, L., Ghattamaneni, R., Ahn, C. H., Nyein, H. Y. Y., Tai, L.-C., & Javey, A. (2020) · Science Advances · doi:10.1126/sciadv.abb8308 · Cited by 154
“Imaging sweat glands and characterizing their densities Two methods were used to image sweat glands using bromophenol dye and iodine patches, respectively, as demonstrated in previous work (25, 26).”
MethodReproductive Hormone Influences on Thermoregulation in Women
Charkoudian, N., & Stachenfeld, N. S. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130029 · Cited by 143
Relf, R., Willmott, A., Flint, M. S., Beale, L., & Maxwell, N. (2019) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2018.12.019 · Cited by 19
Metadata
- Authors
- Gagnon, D., Ganio, M. S., Lucas, R. A. I., Pearson, J., Crandall, C. G., & Kenny, G. P.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2012-04-15
- Volume
- 112
- Issue
- 8
- Pages
- 1419-1425
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2033839212
- Cited by
- 65
- References
- 8
- FWCI
- 2.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.