CoChat

Estimation of critical torque using intermittent isometric maximal voluntary contractions of the quadriceps in humans

Burnley, Mark · 2009 · Journal of Applied Physiology
Cited by 140

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

To determine whether the asymptote of the torque-duration relationship (critical torque) could be estimated from the torque measured at the end of a series of maximal voluntary contractions (MVCs) of the quadriceps, eight healthy men performed eight laboratory tests. Following familiarization, subjects performed two tests in which they were required to perform 60 isometric MVCs over a period of 5 min (3 s contraction, 2 s rest), and five tests involving intermittent isometric contractions at ∼35–60% MVC, each performed to task failure. Critical torque was determined using linear regression of the torque impulse and contraction time during the submaximal tests, and the end-test torque during the MVCs was calculated from the mean of the last six contractions of the test. During the MVCs voluntary torque declined from 263.9 ± 44.6 to 77.8 ± 17.8 N·m. The end-test torque was not different from the critical torque (77.9 ± 15.9 N·m; 95% paired-sample confidence interval, −6.5 to 6.2 N·m). The root mean squared error of the estimation of critical torque from the end-test torque was 7.1 N·m. Twitch interpolation showed that voluntary activation declined from 90.9 ± 6.5% to 66.9 ± 13.1% ( P < 0.001), and the potentiated doublet response declined from 97.7 ± 23.0 to 46.9 ± 6.7 N·m ( P < 0.001) during the MVCs, indicating the development of both central and peripheral fatigue. These data indicate that fatigue during 5 min of intermittent isometric MVCs of the quadriceps leads to an end-test torque that closely approximates the critical torque.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.91474.2008

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 140

Metadata

Authors
Burnley, M.
Venue
Journal of Applied Physiology
Published
2009-03
Volume
106
Issue
3
Pages
975-983
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2100614612
Cited by
140
References
8
FWCI
10.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimation of critical torque using intermittent isometric maximal voluntary contractions of the quadriceps in humans. https://app.cochat.ai/papers/10.1152/japplphysiol.91474.2008
The paper
Burnley, M. (2009). Estimation of critical torque using intermittent isometric maximal voluntary contractions of the quadriceps in humans. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.91474.2008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.