An evaluation of in vivo voltage-sensitive dyes: pharmacological side effects and signal-to-noise ratios after effective removal of brain-pulsation artifacts
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In the current study, we investigated pharmacological side effects and signal-to-noise ratios (SNRs) of two commonly used voltage-sensitive dyes (VSDs): the blue dye RH-1691 (1 mg/ml) and the red dye di-4-ANEPPS (0.1 mg/ml), applied in vivo to the rat barrel cortex. Blue dyes are often favored over red dyes in in vivo studies due to their apparent superior SNR, partly because their fluorescence spectrum is farther away from the hemoglobin absorption spectrum, making them less prone to heartbeat-associated brain-pulsation artifacts (BPA). We implemented a previously reported template-based BPA removal algorithm and evaluated its applicability to di-4-ANEPPS before comparing characteristics of the two dyes. Somatosensory-evoked potentials (SEPs) were also recorded. Whereas SEPs recorded before and after application of di-4-ANEPPS failed to exhibit demonstrable differences, RH-1691 caused a significant and prolonged increase in SEP amplitude for several hours. In contrast, neither dye influenced the spontaneous cortical activity as assessed by the spectral content of the EEG. Both dyes turned out to be strikingly similar with respect to changes in fractional fluorescence as a function of SEP response amplitude, as well as regarding shot noise characteristics after removal of the BPA. Thus there is strong evidence that the increased SNR for RH-1691 is a consequence of an artificially increased signal. When applying an appropriate BPA removal algorithm, di-4-ANEPPS has proven to be suitable for single-trial in vivo VSD imaging (VSDI) and produces no detectable neurophysiological changes in the system under investigation. Taken together, our data argue for a careful re-evaluation of pharmacological side effects of RH-1691 and support the applicability of di-4-ANEPPS for stable single-trial in vivo VSDI recordings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
VSDI: a new era in functional imaging of cortical dynamics
Grinvald, A., & Hildesheim, R. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1536 · Cited by 618
Ferezou, I., Bolea, S., & Petersen, C. C. H. (2006) · Neuron · doi:10.1016/j.neuron.2006.03.043 · Cited by 466
Cited by
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
Spontaneous cortical activity alternates between motifs defined by regional axonal projections
Mohajerani, M. H., Chan, A. W., Mohsenvand, M., LeDue, J., Liu, R., McVea, D. A., Boyd, J. D., Wang, Y. T., Reimers, M., & Murphy, T. H. (2013) · Nature Neuroscience · doi:10.1038/nn.3499 · Cited by 388
Vanni, M. P., & Murphy, T. H. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.1818-14.2014 · Cited by 170
“Moreover, VSD use was associated with side effects, such as enhancement of sensory responses (Grandy et al., 2012; Mohajerani et al., 2013).”
BackgroundImaging the awake visual cortex with a genetically encoded voltage indicator
Carandini, M., Shimaoka, D., Rossi, L. F., Sato, T. K., Benucci, A., & Knöpfel, T. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.0594-14.2015 · Cited by 115
Nag, O. K., Stewart, M. H., Deschamps, J. R., Susumu, K., Oh, E., Tsytsarev, V., Tang, Q., Efros, A. L., Vaxenburg, R., Black, B. J., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b00954 · Cited by 80
“hemodynamic components of the vascular system.(82,86) These dyes respond optically within ~10 ms to applied electrical stimulation and return to baseline within 50-100 ms,(77) comparable to the”
Metadata
- Authors
- Grandy, T. H., Greenfield, S. A., & Devonshire, I. M.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2012-12-01
- Volume
- 108
- Issue
- 11
- Pages
- 2931-2945
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W1975662936
- Cited by
- 36
- References
- 2
- FWCI
- 1.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.