Dipole Source Analysis of Laser-Evoked Subdural Potentials Recorded From Parasylvian Cortex in Humans
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The location of the human nociceptive area(s) near the Sylvian fissure is still controversial in spite of evidence from imaging and evoked potential studies that noxious heat stimuli activate somatosensory areas in that region. Some studies have suggested the secondary somatosensory cortex (SII) on the upper bank of the Sylvian fissure posterior to the central sulcus, others the anterior insula or parietal area 7b. In this study, we applied dipole source analysis techniques to laser-evoked potentials (LEPs) that were recorded from subdural grid electrodes in three patients. As a functional marker, auditory-evoked potentials (AEPs) with a generator on the opposite bank of the Sylvian fissure were recorded from the same electrodes. The LEP global field power (GFP), a measure of spatial variance, showed a first peak at about 150 ms latency, corresponding to the latency of the N1 recorded from the scalp. In contrast to scalp recordings, the amplitude of the first GFP peak recorded from the grid was larger than the second peak (P2). This finding suggests that the generator of N1, but not that of later LEP components, was close to the subdural grids. When a regional source was fitted to the first GFP peak, its location was within the frontoparietal operculum in all patients. On average, the LEP source was 13 mm anterior, 6 mm superior, and 2 mm medial of the AEP source. This relative location also suggests a source within the frontoparietal operculum overlying the insula. At the latency of the first GFP peak, source orientation pointed inward, suggesting a generator within the inner vertical surface of the operculum. Somatotopy was assessed in one patient and was consistent with that of the projection area of the presumed nociceptive thalamic nucleus posterior part of the ventromedial nucleus, but differed from that of SII. These findings suggest that the nociceptive area in human parasylvian cortex that is activated most rapidly by noxious heat pulses may be separate from the tactile SII area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
How do you feel? Interoception: The sense of the physiological condition of the body
Craig, A. D. (2002) · Nature Reviews Neuroscience · doi:10.1038/nrn894 · Cited by 6,006 · cited 2×
“This region was suggested to be an interoceptive cortical area and was found to be activated in PET studies of heat pain, visceral pain, innocuous temperature stimuli, sensual touch, and itch (for review see Craig 2002).”
BackgroundCircuitry and functional aspects of the insular lobe in primates including humans
AUGUSTINE, J. (1996) · Brain Research Reviews · doi:10.1016/s0165-0173(96)00011-2 · Cited by 1,776
Distributed processing of pain and vibration by the human brain
Coghill, R., Talbot, J., Evans, A., Meyer, E., Gjedde, A., Bushnell, M., & Duncan, G. (1994) · The Journal of Neuroscience · doi:10.1523/jneurosci.14-07-04095.1994 · Cited by 808
Association and dissociation between laser-evoked potentials and pain perception
Garcí-Larrea, L., Peyron, R., Laurent, B., & Mauguière, F. (1997) · NeuroReport · doi:10.1097/00001756-199712010-00026 · Cited by 298
Pain sensitivity alterations as a function of lesion location in the parasylvian cortex
Greenspan, J. D., Lee, R. R., & Lenz, F. A. (1999) · Pain · doi:10.1016/s0304-3959(99)00021-4 · Cited by 297 · cited 1×
“…was the only area that was significantly more active during heat pain than during vibration in a PET study (Coghill et al. 1994), but lesions that led to a loss of pain sensitivity in patients had to encompass the operculum (VPI projection target) rather than the insula (Greenspan et al. 1999).”
BackgroundSelf-citation
Cited by
Human brain mechanisms of pain perception and regulation in health and disease
Apkarian, A. V., Bushnell, M. C., Treede, R., & Zubieta, J. (2005) · European Journal of Pain · doi:10.1016/j.ejpain.2004.11.001 · Cited by 3,126
Self-citationCraig, A. D. (. (2010) · Brain Structure and Function · doi:10.1007/s00429-010-0248-y · Cited by 600
Brain generators of laser-evoked potentials: from dipoles to functional significance
Garcia-Larrea, L., Frot, M., & Valeriani, M. (2003) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2003.10.008 · Cited by 541
Brooks, J. C. W., Zambreanu, L., Godinez, A., Craig, A. D. (., & Tracey, I. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.041 · Cited by 355
Persistent EEG overactivation in the cortical pain matrix of neurogenic pain patients
Stern, J., Jeanmonod, D., & Sarnthein, J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.042 · Cited by 334
Metadata
- Authors
- Vogel, H., Port, J. D., Lenz, F. A., Solaiyappan, M., Krauss, G., & Treede, R.-D.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2003-06
- Volume
- 89
- Issue
- 6
- Pages
- 3051-3060
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2065240872
- Cited by
- 109
- References
- 5
- FWCI
- 7.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dipole Source Analysis of Laser-Evoked Subdural Potentials Recorded From Parasylvian Cortex in Humans. https://app.cochat.ai/papers/10.1152/jn.00772.2002
- The paper
- Vogel, H., Port, J. D., Lenz, F. A., Solaiyappan, M., Krauss, G., & Treede, R.-D. (2003). Dipole Source Analysis of Laser-Evoked Subdural Potentials Recorded From Parasylvian Cortex in Humans. Journal of Neurophysiology. https://doi.org/10.1152/jn.00772.2002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.