Cited by 62Tactile and Sensory InteractionsIon Channels and ReceptorsPain Mechanisms and Treatments

Sensations Evoked by Microstimulation of Single Mechanoreceptive Afferents Innervating the Human Face and Mouth

Trulsson, M., Essick, G. K.·2010·Journal of Neurophysiology

Abstract

Intraneural microneurography and microstimulation were performed on single afferent axons in the inferior alveolar and lingual nerves innervating the face, teeth, labial, or oral mucosa. Using natural mechanical stimuli, 35 single mechanoreceptive afferents were characterized with respect to unit type [fast adapting type I (FA I), FA hair, slowly adapting type I and II (SA I and SA II), periodontal, and deep tongue units] as well as size and shape of the receptive field. All afferents were subsequently microstimulated with pulse trains at 30 Hz lasting 1.0 s. Afferents recordings whose were stable thereafter were also tested with single pulses and pulse trains at 5 and 60 Hz. The results revealed that electrical stimulation of single FA I, FA hair, and SA I afferents from the orofacial region can evoke a percept that is spatially matched to the afferent's receptive field and consistent with the afferent's response properties as observed on natural mechanical stimulation. Stimulation of FA afferents typically evoked sensations that were vibratory in nature; whereas those of SA I afferents were felt as constant pressure. These afferents terminate superficially in the orofacial tissues and seem to have a particularly powerful access to perceptual levels. In contrast, microstimulation of single periodontal, SA II, and deep tongue afferents failed to evoke a sensation that matched the receptive field of the afferent. These afferents terminate more deeply in the tissues, are often active in the absence of external stimulation, and probably access perceptual levels only when multiple afferents are stimulated. It is suggested that the spontaneously active afferents that monitor tension in collagen fibers (SA II and periodontal afferents) may have the role to register the mechanical state of the soft tissues, which has been hypothesized to help maintain the body's representation in the central somatosensory system.

Integrity signals

Registry

Crossref · 10.1152/jn.01146.2009

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Four different classes of tactile afferents have been found in the hairy skin of the face and the red zone of the lip: slowly adapting type I and type II, fast-adapting type I, and fast-adapting hair follicle afferents.

    “Four different classes of tactile afferents have been found in the hairy skin of the face and the red zone of the lip: slowly adapting type I and type II, fast-adapting type I and fast-adapting hair follicle afferents (Trulsson and Essick 2010).”

    From Tactile innervation densities across the whole body (2020) · cites this paper as Trulsson and Essick 2010

  • The hair follicle afferents encountered in facial skin are likely similar to hair units described in other hairy skin but appear in some cases associated with a single hair only.

    “The hair follicle afferents (FA hair units) encountered in the facial skin are likely similar to hair units described in other hairy skin but appear in some cases associated with a single hair only (Trulsson and Essick 2010).”

    From Tactile innervation densities across the whole body (2020) · cites this paper as Trulsson and Essick 2010

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Trulsson, M., & Essick, G. K.
Affiliations
  • Karolinska Institutet (SE)
  • University of North Carolina at Chapel Hill (US)
Corresponding author
Trulsson, M.
Venue
Journal of Neurophysiology
Published
2010-04
Volume
103
Issue
4
Pages
1741-1747
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2015182090
Cited by
62
References
4
Citations by year
2026: 2 · 2025: 1 · 2024: 3 · 2023: 4 · 2022: 5 · 2021: 9 · 2020: 4 · 2019: 3 · 2018: 2 · 2017: 5 · 2016: 6 · 2015: 2 · 2014: 4 · 2013: 4 · 2012: 3
FWCI
2.33
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Neurophysiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Life Sciences › Neuroscience › Sensory Systems › Ion Channels and Receptors
  • Health Sciences › Medicine › Physiology › Pain Mechanisms and Treatments
Keywords
microstimulation, inferior alveolar nerve, lingual nerve, receptive fields, vibration perception, pressure sensation, spontaneous activity, somatosensory representation
MeSH terms
Action Potentials, Adult, Electric Stimulation, Face, Female, Humans, Male, Mechanoreceptors, Mouth, Mouth Mucosa, Neurons, Afferent, Sensation, Skin, Stress, Mechanical, Hair Follicle

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review