The DOI matches its Crossref record.
Effects of continuous noise backgrounds on rate response of auditory nerve fibers in cat
Abstract
This study describes the effects of broadband background noise on the average discharge rate to best-frequency (BF) tones of auditory nerve fibers in the cat. The effects of exposure to long-term continuous noise are compared to the effects of noise gated on and off simultaneously with test tones. Addition of background noise causes a shift of the dynamic portion of tone-evoked rate versus level functions to higher tone intensities. The shift occurs at a mean rate of 0.61 dB of shift for each 1-dB increment in noise level. The rate of shift is independent of best frequency and spontaneous discharge rate. The noise level at which the shift begins is frequency dependent and is consistent with the frequency-dependent bandwidths of auditory nerve fiber tuning curves. The adjustment of the dynamic range shows many similarities to two-tone suppression. Therefore, it is most likely that it is caused by suppression of the response to the BF test tone by energy present in the noise at surrounding frequencies. At high noise levels, the ability of auditory nerve fibers to respond to test tones is limited by the rate response to the noise. As noise level increases, the discharge rate it evokes approaches a fiber's saturation rate and ultimately eliminates the fiber's ability to respond to test tones. Low spontaneous rate fibers, which have been shown to have higher thresholds and wider dynamic range (17,29), are significantly more resistant to saturation by high noise levels. Exposure to broadband noise prior to onset of test tones produces an overall decrement in response rate. This phenomenon is similar to the effects of short-term adaptation (32) and seems to develop independently of the shift of dynamic range. At high noise levels, previous exposure to the noise produces a small dynamic range shift. This effect is similar to that produced by suppression but is smaller. The effect is occluded in continuous noise backgrounds by the adjustment of sensitivity produced by suppression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Acoustic Communication in Noise
Brumm, H., & Slabbekoorn, H. (2005) · Advances in the Study of Behavior · doi:10.1016/s0065-3454(05)35004-2 · Cited by 973
Age-Related Cochlear Synaptopathy: An Early-Onset Contributor to Auditory Functional Decline
Sergeyenko, Y., Lall, K., Liberman, M. C., & Kujawa, S. G. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.1783-13.2013 · Cited by 794
Noise-induced cochlear neuropathy is selective for fibers with low spontaneous rates
Furman, A. C., Kujawa, S. G., & Liberman, M. C. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00164.2013 · Cited by 761
Kujawa, S. G., & Liberman, M. C. (2015) · Hearing Research · doi:10.1016/j.heares.2015.02.009 · Cited by 754
Cochlear synaptopathy in acquired sensorineural hearing loss: Manifestations and mechanisms
Liberman, M. C., & Kujawa, S. G. (2017) · Hearing Research · doi:10.1016/j.heares.2017.01.003 · Cited by 706
Metadata
- Authors
- Costalupes, J. A., Young, E. D., & Gibson, D. J.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1984-06-01
- Volume
- 51
- Issue
- 6
- Pages
- 1326-1344
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2203895492
- Cited by
- 260
- References
- 0
- FWCI
- 2.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of continuous noise backgrounds on rate response of auditory nerve fibers in cat. https://app.cochat.ai/papers/10.1152/jn.1984.51.6.1326
- The paper
- Costalupes, J. A., Young, E. D., & Gibson, D. J. (1984). Effects of continuous noise backgrounds on rate response of auditory nerve fibers in cat. Journal of Neurophysiology. https://doi.org/10.1152/jn.1984.51.6.1326
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.