The DOI matches its Crossref record.
Grip force adjustments evoked by load force perturbations of a grasped object
Abstract
1. Brief increases or decreases in vertical load force were applied to an object held between the thumb and finger. Grip force increases occurred consistently from 60 to 90 ms after onset of the load force increase. These responses did not adapt and were typically from 100 to 200 ms in duration. Reductions in object load force yielded rapid reductions in grip force at latencies comparable to those for load increases. 2. Response magnitude was proportional to the size or velocity of the load force increment, but did not vary with the level of the preexisting grip force. Thus these responses did not maintain the grip force at a specified level above the object's slip point. 3. Grip force responses were abolished or substantially reduced when loads were delivered directly to the hand rather than to the object. In contrast, force responses were not always abolished upon anesthetization of the thumb and finger. These results are discussed in relation to the role of cutaneous mechano-receptors of the digital pulps and proprioceptors of the arm and hand for providing necessary afferent information utilized in load-related grip force modulation. 4. Rapid and automatic grip force adjustments to load force variations may contribute importantly to grasp tasks in which the load forces vary dynamically and without complete predictability, such as in the manipulation of tools or objects that contact the environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Prediction Precedes Control in Motor Learning
Flanagan, J. R., Vetter, P., Johansson, R. S., & Wolpert, D. M. (2003) · Current Biology · doi:10.1016/s0960-9822(03)00007-1 · Cited by 494
Johansson, R. S., Riso, R., Häger, C., & Bäckström, L. (1992) · Experimental Brain Research · doi:10.1007/bf00229015 · Cited by 274
The Effects of Digital Anesthesia on Force Control Using a Precision Grip
Monzée, J., Lamarre, Y., & Smith, A. M. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00434.2001 · Cited by 266
The stability of precision grip forces during cyclic arm movements with a hand-held load
Flanagan, J. R., & Wing, A. (1990) · Experimental Brain Research · doi:10.1007/bf00233045 · Cited by 263
Metadata
- Authors
- Cole, K. J., & Abbs, J. H.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1988-10-01
- Volume
- 60
- Issue
- 4
- Pages
- 1513-1522
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W1898175507
- Cited by
- 214
- References
- 0
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Grip force adjustments evoked by load force perturbations of a grasped object. https://app.cochat.ai/papers/10.1152/jn.1988.60.4.1513
- The paper
- Cole, K. J., & Abbs, J. H. (1988). Grip force adjustments evoked by load force perturbations of a grasped object. Journal of Neurophysiology. https://doi.org/10.1152/jn.1988.60.4.1513
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.