Cited by 266Motor Control and AdaptationTactile and Sensory InteractionsTeleoperation and Haptic Systems

The Effects of Digital Anesthesia on Force Control Using a Precision Grip

Monzée, Joël, Lamarre, Yves, Smith, Allan M.·2003·Journal of Neurophysiology

Abstract

A total of 20 right-handed subjects were asked to perform a grasp-lift-and-hold task using a precision grip. The grasped object was a one-degree-of-freedom manipuladum consisting of a vertically mounted linear motor capable of generating resistive forces to simulate a range of object weights. In the initial study, seven subjects (6 women, 1 man; ages 24–56 yr) were first asked to lift and hold the object stationary for 4 s. The object presented a metal tab with two different surface textures and offered one of four resistive forces (0.5, 1.0, 1.5, and 2.0 N). The lifts were performed both with and without visual feedback. Next, the subjects were asked to perform the same grasping sequence again after ring block anesthesia of the thumb and index finger with mepivacaine. The objective was to determine the degree to which an internal model obtained through prior familiarity might compensate for the loss of cutaneous sensation. In agreement with previous studies, it was found that all subjects applied significantly greater grip force after digital anesthesia, and the coordination between grip and load forces was disrupted. It appears from these data, that the internal model alone is insufficient to completely compensate for the loss of cutaneous sensation. Moreover, the results suggest that the internal model must have either continuous tonic excitation from cutaneous receptors or at least frequent intermittent reiteration to function optimally. A subsequent study performed with 10 additional subjects (9 women, 1 man; ages 24–49 yr) indicated that with unimpaired cutaneous feedback, the grasping and lifting forces were applied together with negligible forces and torques in other directions. In contrast, after digital anesthesia, significant additional linear and torsional forces appeared, particularly in the horizontal and frontal planes. These torques were thought to arise partially from the application of excessive grip force and partially from a misalignment of the two grasping fingers. These torques were further increased by an imbalance in the pressure exerted by the two opposing fingers. Vision of the grasping hand did not significantly correct the finger misalignment after digital anesthesia. Taken together, these results suggest that mechanoreceptors in the fingertips signal the source and direction of pressure applied to the skin. The nervous system uses this information to adjust the fingers and direct the pinch forces optimally for grasping and object manipulation.

Integrity signals

Registry

Crossref · 10.1152/jn.00434.2001

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Monzée, J., Lamarre, Y., & Smith, A. M.
Affiliations
Université de Montréal (CA)
Venue
Journal of Neurophysiology
Published
2003-02-01
Volume
89
Issue
2
Pages
672-683
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2013366385
Cited by
266
References
0
Citations by year
2026: 7 · 2025: 9 · 2024: 8 · 2023: 12 · 2022: 10 · 2021: 23 · 2020: 14 · 2019: 16 · 2018: 9 · 2017: 7 · 2016: 12 · 2015: 15 · 2014: 18 · 2013: 15 · 2012: 14
FWCI
4.88
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Neurophysiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
Keywords
precision grip, grip force control, skin sensation, internal models, mechanoreceptors, tactile feedback, mepivacaine, pinch strength, visual feedback, object weight perception
MeSH terms
Adult, Anesthetics, Local, Female, Fingers, Humans, Male, Middle Aged, Movement, Polyneuropathies, Pressure, Skin, Thumb, Touch, Hand Strength, Torque

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review