CoChat

Analysis of effective synaptic currents generated by homonymous Ia afferent fibers in motoneurons of the cat

Heckman, C. J., Binder, M. D. · 1988 · Journal of Neurophysiology
Cited by 140

The DOI matches its Crossref record.

Abstract

1. We have developed a technique to measure the total amount of current from a synaptic input system that reaches the soma of a motoneuron under steady-state conditions. We refer to this quantity as the effective synaptic current (IN) because only that fraction of the synaptic current that actually reaches the soma and initial segment of the cell affects its recruitment threshold and firing frequency. 2. The advantage of this technique for analysis of synaptic inputs in comparison to the standard measurements of synaptic potentials is apparent from Ohm's law. Steady-state synaptic potentials recorded at the soma of a cell are the product of IN and input resistance (RN), which is determined by intrinsic cellular properties such as cell size and membrane resistivity. Measuring IN avoids the confounding effect of RN on the amplitudes of synaptic potentials and thus provides a more direct assessment of the magnitude of a synaptic input. 3. Steady-state synaptic inputs were generated in cat medial gastrocnemius (MG) motoneurons by using tendon vibration to activate homonymous Ia afferents. We found that the magnitude of the Ia effective synaptic current (Ia IN) was not the same in all MG cells. Instead, Ia IN covaried with RN (r = 0.64; P less than 0.001), being about twice as large on average in motoneurons with high RN values as in those with low RN values. Ia IN was also correlated with motoneuron rheobase, afterhyperpolarization duration, and axonal conduction velocity. 4. A comparison of transient Ia EPSPs with steady-state Ia EPSPs (Ia EPSPSS) evoked in the same cells suggested that the effective synaptic current that produces the transient Ia EPSP was also greater in motoneurons with high RN values than in those with low RN values. 5. The factors responsible for the Ia IN-RN covariance are uncertain. However, our finding greater values of Ia IN in high RN motoneurons is consistent with other evidence suggesting that Ia boutons on these motoneurons have a higher probability for neurotransmitter release than those on low RN motoneurons (19). 6. The neural mechanisms underlying orderly recruitment are discussed. The effect of the Ia input is to produce an approximately twofold expansion of the differences in motoneuron recruitment thresholds that are generated by intrinsic cellular properties. It is suggested that the higher efficacy of Ia input in low-threshold motoneurons confers particular importance on this input system in the control of vernier movements (7).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1988.60.6.1946

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 140

Metadata

Authors
Heckman, C. J., & Binder, M. D.
Venue
Journal of Neurophysiology
Published
1988-12-01
Volume
60
Issue
6
Pages
1946-1966
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2440168604
Cited by
140
References
0
FWCI
0.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analysis of effective synaptic currents generated by homonymous Ia afferent fibers in motoneurons of the cat. https://app.cochat.ai/papers/10.1152/jn.1988.60.6.1946
The paper
Heckman, C. J., & Binder, M. D. (1988). Analysis of effective synaptic currents generated by homonymous Ia afferent fibers in motoneurons of the cat. Journal of Neurophysiology. https://doi.org/10.1152/jn.1988.60.6.1946

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.