Human cortical potentials evoked by stimulation of the median nerve. II. Cytoarchitectonic areas generating long-latency activity
The DOI matches its Crossref record.
Abstract
1. The anatomic generators of human median nerve somatosensory evoked potentials (SEPs) in the 40 to 250-ms latency range were investigated in 54 patients by means of cortical-surface and transcortical recordings obtained during neurosurgery. 2. Contralateral stimulation evoked three groups of SEPs recorded from the hand representation area of sensorimotor cortex: P45-N80-P180, recorded anterior to the central sulcus (CS) and maximal on the precentral gyrus; N45-P80-N180, recorded posterior to the CS and maximal on the postcentral gyrus; and P50-N90-P190, recorded near and on either side of the CS. 3. P45-N80-P180 inverted in polarity to N45-P80-N180 across the CS but was similar in polarity from the cortical surface and white matter in transcortical recordings. These spatial distributions were similar to those of the short-latency P20-N30 and N20-P30 potentials described in the preceding paper, suggesting that these long-latency potentials are generated in area 3b of somatosensory cortex. 4. P50-N90-P190 was largest over the anterior one-half of somatosensory cortex and did not show polarity inversion across the CS. This spatial distribution was similar to that of the short-latency P25-N35 potentials described in the preceding paper and, together with our and Goldring et al. 1970; Stohr and Goldring 1969 transcortical recordings, suggest that these long-latency potentials are generated in area 1 of somatosensory cortex. 5. SEPs of apparently local origin were recorded from several regions of sensorimotor cortex to stimulation of the ipsilateral median nerve. Surface and transcortical recordings suggest that the ipsilateral potentials are generated not in area 3b, but rather in other regions of sensorimotor cortex perhaps including areas 4, 1, 2, and 7. This spatial distribution suggests that the ipsilateral potentials are generated by transcallosal input from the contralateral hemisphere. 6. Recordings from the periSylvian region were characterized by P100 and N100, recorded above and below the Sylvian sulcus (SS) respectively. This distribution suggests a tangential generator located in the upper wall of the SS in the second somatosensory area (SII). In addition, N125 and P200, recorded near and on either side of the SS, suggest a radial generator in a portion of SII located in surface cortex above the SS. 7. In comparison with the short-latency SEPs described in the preceding paper, the long-latency potentials were more variable and were more affected by intraoperative conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Allison, T. (1999) · Cerebral Cortex · doi:10.1093/cercor/9.5.415 · Cited by 882
Self-citationBrain generators of laser-evoked potentials: from dipoles to functional significance
Garcia-Larrea, L., Frot, M., & Valeriani, M. (2003) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2003.10.008 · Cited by 541
Functional Organization of the Human First and Second Somatosensory Cortices: a Neuromagnetic Study
Hari, R., Karhu, J., Hämäläinen, M., Knuutila, J., Salonen, O., Sams, M., & Vilkman, V. (1993) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.1993.tb00536.x · Cited by 476
Image-Guided Transcranial Focused Ultrasound Stimulates Human Primary Somatosensory Cortex
Lee, W., Kim, H., Jung, Y., Song, I.-U., Chung, Y. A., & Yoo, S.-S. (2015) · Scientific Reports · doi:10.1038/srep08743 · Cited by 414
Magnetoencephalography in the study of human somatosensory cortical processing
Hari, R., & Forss, N. (1999) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1999.0470 · Cited by 338
Neuromodulation with single‐element transcranial focused ultrasound in human thalamus
Legon, W., Ai, L., Bansal, P., & Mueller, J. K. (2018) · Human Brain Mapping · doi:10.1002/hbm.23981 · Cited by 334
Intracranial EEG and human brain mapping
Lachaux, J. P., Rudrauf, D., & Kahane, P. (2003) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2004.01.018 · Cited by 331
Puce, A., Constable, R. T., Luby, M. L., McCarthy, G., Nobre, A. C., Spencer, D. D., Gore, J. C., & Allison, T. (1995) · Journal of Neurosurgery · doi:10.3171/jns.1995.83.2.0262 · Cited by 312
Self-citationParallel Activation of Primary and Secondary Somatosensory Cortices in Human Pain Processing
Ploner, M., Schmitz, F., Freund, H.-J., & Schnitzler, A. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.81.6.3100 · Cited by 283
Allison, T., McCarthy, G., & Wood, C. C. (1992) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(92)90082-m · Cited by 278
Self-citationMima, T., Nagamine, T., Nakamura, K., & Shibasaki, H. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.80.4.2215 · Cited by 277
Mauguière, F., Merlet, I., Forss, N., Vanni, S., Jousmäki, V, Adeleine, P., & Hari, R. (1997) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/s0013-4694(97)00006-0 · Cited by 256
High resolution EEG: 124-channel recording, spatial deblurring and MRI integration methods
Gevins, A., Le, J., Martin, N. K., Brickett, P., Desmond, J., & Reutter, B. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90050-7 · Cited by 246
“The maximum and minimum deblurred potentials are situated on either side of the central sulcus, which is consistent with a tangential generator situated within the posterior bank of the central sulcus (Allison 1987; Allison et al. 1989a,b).”
Transient Suppression of Ipsilateral Primary Somatosensory Cortex during Tactile Finger Stimulation
Hlushchuk, Y., & Hari, R. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.5536-05.2006 · Cited by 244
“…the human primary somatosensory (SI) cortex is activated only by contralateral tactile stimuli, whereas the more posterior parietal cortex (possibly areas 1, 2, and 5) may display short- and long-latency responses also to ipsilateral activation of the somatosensory afferents (Allison et al., 1989).”
BackgroundInfluentialfMRI of the Responses to Vibratory Stimulation of Digit Tips
Francis, S. T., Kelly, E. F., Bowtell, R., Dunseath, W. J. R., Folger, S. E., & McGlone, F. (2000) · NeuroImage · doi:10.1006/nimg.2000.0541 · Cited by 242
Mazzola, L., Isnard, J., & Mauguière, F. (2006) · Cerebral Cortex · doi:10.1093/cercor/bhj038 · Cited by 197
Fingertip Representation in the Human Somatosensory Cortex: An fMRI Study
Gelnar, P. A., Krauss, B. R., Szeverenyi, N. M., & Apkarian, A. V. (1998) · NeuroImage · doi:10.1006/nimg.1998.0341 · Cited by 190
Somatosensory processing during movement observation in humans
Rossi, S., Tecchio, F., Pasqualetti, P., Ulivelli, M., Pizzella, V, Romani, G. L., Passero, S., Battistini, N., & Rossini, P. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00725-8 · Cited by 178
The effect of different anesthetics on neurovascular coupling
Franceschini, M. A., Radhakrishnan, H., Thakur, K., Wu, W., Ruvinskaya, S., Carp, S., & Boas, D. A. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.060 · Cited by 173
“…have a similar structure, consisting first of a large and narrow positive component, P1, followedwithin 10 ms by a large negative component, N1, and then by two slow components, P2 and N2, tens of ms after N1 (Allison et al., 1989; Arezzo et al., 1981; Di and Barth, 1991; Kulics and Cauller, 1986).”
BackgroundNeural generators of early cortical somatosensory evoked potentials in the awake monkey
Peterson, N. N., Schroeder, C. E., & Arezzo, J. C. (1995) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(95)00006-e · Cited by 164
Short- and long-latency afferent inhibition; uses, mechanisms and influencing factors
Turco, C. V., El-Sayes, J., Savoie, M. J., Fassett, H. J., Locke, M. B., & Nelson, A. J. (2018) · Brain Stimulation · doi:10.1016/j.brs.2017.09.009 · Cited by 160
“009 hemisphere via the corpus callosum (~13e20ms) [11,33].”
MethodVision of the body modulates processing in primary somatosensory cortex
Longo, M. R., Pernigo, S., & Haggard, P. (2011) · Neuroscience Letters · doi:10.1016/j.neulet.2010.12.007 · Cited by 57
Metadata
- Authors
- Allison, T., McCarthy, G., Wood, C. C., Williamson, P. D., & Spencer, D. D.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1989-09-01
- Volume
- 62
- Issue
- 3
- Pages
- 711-722
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W4297742769
- Cited by
- 300
- References
- 0
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.