Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 409

The DOI matches its Crossref record.

Low- and high-frequency membrane potential oscillations during theta activity in CA1 and CA3 pyramidal neurons of the rat hippocampus under ketamine-xylazine anesthesia

Soltesz, I., Deschenes, M.·1993·Journal of Neurophysiology

Abstract

1. Intracellularly recorded low- and high-frequency (4-6 and 25-50 Hz, respectively), rhythmic, spontaneous membrane potential oscillations were investigated in pyramidal neurons of the rat hippocampus in vivo, during theta (theta, 4-6 Hz) electroencephalographic (EEG) activity, under ketamine-xylazine anesthesia. 2. The EEG activity showed two spectral peaks, one in the theta range, the other at higher frequencies (25-50 Hz). On the basis of their electrophysiological and pharmacological properties, it was concluded that the EEG theta-waves, and the fast EEG rhythm, recorded during ketamine-xylazine anesthesia, share the basic properties of those theta and fast rhythms that are recorded under the effects of other types of anesthetics. 3. When intracellular recordings (n = 32) were made with electrodes filled with potassium-acetate (K-acetate), the only CA1 and CA3 pyramidal cells (PCs) considered for further analysis were those that did not fire rhythmically at most or each cycle of the theta rhythm at the resting membrane potential. During EEG-theta, the membrane potential (Vm) of these cells showed a prominent oscillation (3-15 mV) with frequencies similar to those of the EEG-theta (the intracellular theta rhythm, intra-theta). 4. The frequency of the intra-theta was independent of the Vm. However, the phase difference between the intra-theta and the EEG-theta was voltage dependent in both types of cells. CA1 PCs showed a large (120-180 degrees, where 360 degrees is the full cycle), gradual shift in the phase difference between the intra-theta and the EEG-theta, when the membrane was hyperpolarized to -85 from -65 mV. Although CA3 PCs displayed a larger variability in their phase-voltage relations, a voltage-dependent phase shift (90-180 degrees) could be observed in CA3 PCs as well. 5. Although the amplitude of the intra-theta in both CA1 and CA3 PCs could display large, sudden, spontaneous changes at a given Vm, the amplitude-Vm plots tended to show a minimum between -70 and -80 mV. Spontaneous changes in the amplitude of the intra-theta did not affect the phase difference between the intra- and the EEG-theta rhythms. 6. Intracellular injection of QX-314 (50-100 mM) did not change the phase-Vm or the amplitude-Vm relationships of CA1 PCs. 7. Intracellular injection of chloride (Cl-) ions greatly reduced the voltage dependency of the phase difference and revealed fast (duration: 20-25 ms), depolarizing potentials (5-20 mV), which appeared at high frequencies (25-50 Hz), amplitude modulated at theta-frequencies.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1993.70.1.97

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 409

Metadata

Authors
Soltesz, I., & Deschenes, M.
Venue
Journal of Neurophysiology
Published
1993-07-01
Volume
70
Issue
1
Pages
97-116
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2105148858
Cited by
409
References
0
FWCI
7.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low- and high-frequency membrane potential oscillations during theta activity in CA1 and CA3 pyramidal neurons of the rat hippocampus under ketamine-xylazine anesthesia. https://app.cochat.ai/papers/10.1152/jn.1993.70.1.97
The paper
Soltesz, I., & Deschenes, M. (1993). Low- and high-frequency membrane potential oscillations during theta activity in CA1 and CA3 pyramidal neurons of the rat hippocampus under ketamine-xylazine anesthesia. Journal of Neurophysiology. https://doi.org/10.1152/jn.1993.70.1.97

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.