Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 236

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

In vivo measurement of human wrist extensor muscle sarcomere length changes

Lieber, R. L., Loren, G. J., Friden, J.·1994·Journal of Neurophysiology

Abstract

1. Human extensor carpi radialis brevis (ECRB) sarcomere length was measured intraoperatively in five subjects using laser diffraction. 2. In a separate cadaveric study, ECRB tendons were loaded to the muscle's predicted maximum tetanic tension, and tendon strain was measured to estimate active sarcomere shortening at the expense of tendon lengthening. 3. As the wrist joint was passively flexed from full extension to full flexion, ECRB sarcomere length increased from 2.6 to 3.4 microns at a rate of 7.6 nm/deg joint angle rotation. Correcting for tendon elongation during muscle activation yielded an active sarcomere length range of 2.44 to 3.33 microns. Maximal predicted sarcomere shortening accompanying muscle activation was dependent on initial sarcomere length and was always < 0.15 microns, suggesting a minimal effect of tendon compliance. 4. Thin filament lengths measured from electron micrographs of muscle biopsies obtained from the same region of the ECRB muscles were 1.30 +/- .027 (SE) microns whereas thick filaments were 1.66 +/- .027 microns long, suggesting an optimal sarcomere length of 2.80 microns and a maximum sarcomere length for active force generation of 4.26 microns. 5. These experiments demonstrate that human skeletal muscles can function on the descending limb of their sarcomere length-tension relationship under physiological conditions. Thus, muscle force changes during joint rotation are an important component of the motor control system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1994.71.3.874

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 236

Metadata

Authors
Lieber, R. L., Loren, G. J., & Friden, J.
Venue
Journal of Neurophysiology
Published
1994-03-01
Volume
71
Issue
3
Pages
874-881
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2151042565
Cited by
236
References
2
FWCI
6.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In vivo measurement of human wrist extensor muscle sarcomere length changes. https://app.cochat.ai/papers/10.1152/jn.1994.71.3.874
The paper
Lieber, R. L., Loren, G. J., & Friden, J. (1994). In vivo measurement of human wrist extensor muscle sarcomere length changes. Journal of Neurophysiology. https://doi.org/10.1152/jn.1994.71.3.874

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.