CoChat

Contractile properties of single motor units in human toe extensors assessed by intraneural motor axon stimulation

Macefield, V. G., Fuglevand, A. J., Bigland-Ritchie, B. · 1996 · Journal of Neurophysiology
Cited by 143

The DOI matches its Crossref record.

Abstract

1. Single motor axons innervating human toe extensor muscles were selectively stimulated through a tungsten microelectrode inserted percutaneously into the peroneal nerve. Twitch and tetanic forces were measured from a strain gauge over the proximal phalanx of the toe generating the greatest force. Twitch data were obtained from 19 single motor units in nine subjects: 8 motor units supplied extensor hallucis longus (EHL), 5 motor units supplied extensor digitorum longus (EDL), and 6 motor units supplied extensor digitorum brevis (EDB). Unpotentiated twitch forces ranged from 6.3 to 78.1 mN (20.0 +/- 4.0 mN, mean +/- SE), with the distribution highly skewed toward small forces. Twitch contraction and half-relaxation times were 74.8 +/- 3.9 and 78.6 +/- 6.0 ms, respectively. Compared with motor units in human thenar muscles, those in human toe extensor muscles were stronger but slower. However, as in thenar motor units, twitch force and contraction time were not related. 2. Force-frequency relationships were determined for 13 units (5 EDL, 5 EHL, 3 EDB) by stimulating each unit with short trains (1.0-5.0 s) of constant frequency (2-100 Hz). Peak force was related to stimulus frequency in a sigmoid fashion. The steep region of the curve extended from 5.5 +/- 0.7 (SE) Hz to 16.3 +/- 1.1 Hz for all units, and the stimulus frequency required to generate half-maximal force (9.6 +/- 0.6 Hz) was close to the center of the steep range. This frequency, which was inversely related to twitch contraction time, was lower than the frequency required to develop half-maximal force of human thenar motor units (12 +/- 4 Hz, mean +/- SD). The slopes of the regression lines relating force to frequency, computed over the steep range for each unit, were also lower for the toe extensors (3.7 +/- 0.7 mN/Hz) than for the thenar muscles (6 +/- 1 mN/Hz). 3. Maximal tetanic forces ranged from 29.9 to 188.1 mN (89.0 +/- 16.5 mN, mean +/- SE), and were generated at stimulus frequencies from 15 to 100 Hz (median 50 Hz). The stimulation frequency required for fused tetani (absence of noticeable force fluctuation) was generally less than that required for maximum tetanic force. The mean twitch-tetanus ratio, calculated for unpotentiated twitches, was 0.22 +/- 0.02 (range 0.15-0.41). This ratio was higher than for human thenar motor units (0.14 +/- 0.06, mean +/- SE). After twitch potentiation of 10 units, the mean twitch-tetanus ratio increased to 0.28 +/- 0.04. 4. The effects of preceding each stimulus train with a short interstimulus interval (10 ms) on force production at each frequency were examined in nine motor units. Peak forces at the onset of each contraction were higher when such an “initial doublet” preceded stimulus trains of < or = 20 Hz, but the mean force at the end of each stimulus train was not significantly affected at any frequency. 5. Eight units were stimulated with a train that increased in frequency continuously from 2 to 80 Hz, and then decreased symmetrically. This pattern resulted in peak forces that were higher on the descending limb of the stimulus train, the force-frequency relationship tracing a hysteresis loop. Hysteresis was exhibited because damping in the neuromuscular system causes the mechanical output of muscle to lag behind neural input. Thus, in non-steady-state conditions (as in most forms of natural activity), somewhat higher firing rates may be required to attain a particular level of force; once attained, force output will be transiently unresponsive to diminution of firing rate. 6. We conclude that there are differences in the contractile properties of single motor units in human toe extensor muscles (involved in posture and locomotion) and thenar muscles (involved in prehension and manipulation). Twitch-tetanus ratios were greater for motor units in the toe extensors, and this property accounted for the lower force sensitivity of these units to increases in frequency. (ABSTRACT TRUNCATED)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1996.75.6.2509

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 143

Metadata

Authors
Macefield, V. G., Fuglevand, A. J., & Bigland-Ritchie, B.
Venue
Journal of Neurophysiology
Published
1996-06-01
Volume
75
Issue
6
Pages
2509-2519
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W165158238
Cited by
143
References
0
FWCI
5.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Contractile properties of single motor units in human toe extensors assessed by intraneural motor axon stimulation. https://app.cochat.ai/papers/10.1152/jn.1996.75.6.2509
The paper
Macefield, V. G., Fuglevand, A. J., & Bigland-Ritchie, B. (1996). Contractile properties of single motor units in human toe extensors assessed by intraneural motor axon stimulation. Journal of Neurophysiology. https://doi.org/10.1152/jn.1996.75.6.2509

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.