Contractile properties of single motor units in human toe extensors assessed by intraneural motor axon stimulation
The DOI matches its Crossref record.
Abstract
1. Single motor axons innervating human toe extensor muscles were selectively stimulated through a tungsten microelectrode inserted percutaneously into the peroneal nerve. Twitch and tetanic forces were measured from a strain gauge over the proximal phalanx of the toe generating the greatest force. Twitch data were obtained from 19 single motor units in nine subjects: 8 motor units supplied extensor hallucis longus (EHL), 5 motor units supplied extensor digitorum longus (EDL), and 6 motor units supplied extensor digitorum brevis (EDB). Unpotentiated twitch forces ranged from 6.3 to 78.1 mN (20.0 +/- 4.0 mN, mean +/- SE), with the distribution highly skewed toward small forces. Twitch contraction and half-relaxation times were 74.8 +/- 3.9 and 78.6 +/- 6.0 ms, respectively. Compared with motor units in human thenar muscles, those in human toe extensor muscles were stronger but slower. However, as in thenar motor units, twitch force and contraction time were not related. 2. Force-frequency relationships were determined for 13 units (5 EDL, 5 EHL, 3 EDB) by stimulating each unit with short trains (1.0-5.0 s) of constant frequency (2-100 Hz). Peak force was related to stimulus frequency in a sigmoid fashion. The steep region of the curve extended from 5.5 +/- 0.7 (SE) Hz to 16.3 +/- 1.1 Hz for all units, and the stimulus frequency required to generate half-maximal force (9.6 +/- 0.6 Hz) was close to the center of the steep range. This frequency, which was inversely related to twitch contraction time, was lower than the frequency required to develop half-maximal force of human thenar motor units (12 +/- 4 Hz, mean +/- SD). The slopes of the regression lines relating force to frequency, computed over the steep range for each unit, were also lower for the toe extensors (3.7 +/- 0.7 mN/Hz) than for the thenar muscles (6 +/- 1 mN/Hz). 3. Maximal tetanic forces ranged from 29.9 to 188.1 mN (89.0 +/- 16.5 mN, mean +/- SE), and were generated at stimulus frequencies from 15 to 100 Hz (median 50 Hz). The stimulation frequency required for fused tetani (absence of noticeable force fluctuation) was generally less than that required for maximum tetanic force. The mean twitch-tetanus ratio, calculated for unpotentiated twitches, was 0.22 +/- 0.02 (range 0.15-0.41). This ratio was higher than for human thenar motor units (0.14 +/- 0.06, mean +/- SE). After twitch potentiation of 10 units, the mean twitch-tetanus ratio increased to 0.28 +/- 0.04. 4. The effects of preceding each stimulus train with a short interstimulus interval (10 ms) on force production at each frequency were examined in nine motor units. Peak forces at the onset of each contraction were higher when such an “initial doublet” preceded stimulus trains of < or = 20 Hz, but the mean force at the end of each stimulus train was not significantly affected at any frequency. 5. Eight units were stimulated with a train that increased in frequency continuously from 2 to 80 Hz, and then decreased symmetrically. This pattern resulted in peak forces that were higher on the descending limb of the stimulus train, the force-frequency relationship tracing a hysteresis loop. Hysteresis was exhibited because damping in the neuromuscular system causes the mechanical output of muscle to lag behind neural input. Thus, in non-steady-state conditions (as in most forms of natural activity), somewhat higher firing rates may be required to attain a particular level of force; once attained, force output will be transiently unresponsive to diminution of firing rate. 6. We conclude that there are differences in the contractile properties of single motor units in human toe extensor muscles (involved in posture and locomotion) and thenar muscles (involved in prehension and manipulation). Twitch-tetanus ratios were greater for motor units in the toe extensors, and this property accounted for the lower force sensitivity of these units to increases in frequency. (ABSTRACT TRUNCATED)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Spinal and Supraspinal Factors in Human Muscle Fatigue
Gandevia, S. C. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.4.1725 · Cited by 3,645
Fiber Types in Mammalian Skeletal Muscles
Schiaffino, S., & Reggiani, C. (2011) · Physiological Reviews · doi:10.1152/physrev.00031.2010 · Cited by 3,022
“For example, maximal force is attained at a frequency of 50 Hz in human muscles in situ (513), while rat fast motor units reach tetanic fusion only above 100 Hz and slow motor units above 70 Hz (613).”
BackgroundFolland, J. P., & Williams, A. G. (2007) · Sports Medicine · doi:10.2165/00007256-200737020-00004 · Cited by 1,347
Sources of Signal-Dependent Noise During Isometric Force Production
Jones, K. E., Hamilton, A. F. D. C., & Wolpert, D. M. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.3.1533 · Cited by 562
Moritz, C. T., Barry, B. K., Pascoe, M. A., & Enoka, R. M. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01122.2004 · Cited by 429
Heckman, C. J., & Enoka, R. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100087 · Cited by 414
Motor unit physiology: Some unresolved issues
Enoka, R. M., & Fuglevand, A. J. (2001) · Muscle & Nerve · doi:10.1002/1097-4598(200101)24:1<4::aid-mus13>3.0.co;2-f · Cited by 390
Self-citationTraining adaptations in the behavior of human motor units
Duchateau, J., Semmler, J. G., & Enoka, R. M. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00543.2006 · Cited by 354
Motor unit firing rates and contractile properties in tibialis anterior of young and old men
Connelly, D. M., Rice, C. L., Roos, M. R., & Vandervoort, A. A. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.2.843 · Cited by 340
“(30) found that the toe extensor MUs in young adults had slower contractile speeds and lower firing rates than did MUs recorded from the thenar muscles of the hand.”
BackgroundHuman motor unit recordings: Origins and insight into the integrated motor system
Duchateau, J., & Enoka, R. M. (2011) · Brain Research · doi:10.1016/j.brainres.2011.06.011 · Cited by 238
Multiple Features of Motor-Unit Activity Influence Force Fluctuations During Isometric Contractions
Taylor, A. M., Christou, E. A., & Enoka, R. M. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00056.2003 · Cited by 232
“The force that a motor unit exerts depends on the rate at which the motor neuron discharges action potentials (Macefield et al. 1996; Thomas et al. 1991).”
BackgroundNeuromuscular activation and motor-unit firing characteristics in cerebral palsy
Rose, J., & McGill, K. C. (2005) · Developmental Medicine & Child Neurology · doi:10.1017/s0012162205000629 · Cited by 211
Cheng, E. J., Brown, I. E., & Loeb, G. E. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00258-2 · Cited by 197
“Although 'sag' is not evident in some human fiber types, (thenar units, Thomas et al., 1991; toe extensor units, Macefield et al., 1996) it is clearly evident in others (triceps surae; van Zandwijk et al., 1998) so we have included it until further evidence can clarify this issue.”
BackgroundCatchlike property of skeletal muscle: Recent findings and clinical implications
Binder‐Macleod, S., & Kesar, T. (2005) · Muscle & Nerve · doi:10.1002/mus.20290 · Cited by 78
Schiefer, M. A., Tyler, D. J., & Triolo, R. J. (2012) · Journal of Computational Neuroscience · doi:10.1007/s10827-011-0381-5 · Cited by 53
The methodology and scope of human microneurography
Gandevia, S. C., & Hales, J. P. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02243-7 · Cited by 39
Metadata
- Authors
- Macefield, V. G., Fuglevand, A. J., & Bigland-Ritchie, B.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1996-06-01
- Volume
- 75
- Issue
- 6
- Pages
- 2509-2519
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W165158238
- Cited by
- 143
- References
- 0
- FWCI
- 5.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.